Item(s) Added To Your Bag
Metravi 11+ Universal Source Calibrator
Metravi 11+ Universal Source Calibrator
(Based On 10 Reviews)
6 Digits, 0.2% Accuracy, Sources R, S, B, E, K, J, T, N types of thermocouples, PT-100, Cu-50, DC Voltage, DC Current, Resistance, Analogue Transducer, Frequency, Pulse Output and LOOP Power.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL PRODUCTS
SECURE PAYMENTS
1 YEAR WARRANTY
AUTHORIZED DISTRIBUTOR
B2B INVOICES
₹ 80,950
(GST inclusive price) i-
Base Value: ₹ 68601.7
-
GST: (18) % ₹ 12348.3
-
Total Value ₹ 80950
₹1,15,763.00
( - 30% OFF )
Description
Key Features
- 6-digit display – High-resolution backlit screen.
- ±0.02% accuracy – Precise voltage and current readings.
- DC voltage source – Up to 10 V.
- DC current source – Up to 20 mA, 1 µA resolution.
- Resistance source – Multiple ranges up to 40 kΩ.
- Step output – 25% / 100% step functions.
- Thermocouple support – TC sourcing with cold junction compensation.
- °C / °F conversion – Easy unit switching.
- Auto power off – Battery saving.
- Battery operated – Fully portable design.
What's in the box?
|
Rating & Reviews
Rating
Function | Reference | Range | Reolution | Accuracy | Remark |
DC voltage | 100mV | -10.000~110.000mV | 1μV | 0.02+0.01 | Maximum output: 0.5mA |
1000mV | -100.00~1100.00mV | 10μV | 0.02+0.01 | Maximum output:2mA | |
10V | -1.0000~11.0000V | 0.1mV | 0.02+0.01 | Maximum output: 5mA | |
DC current | 20mA | 0.000mA~22.000mA | 1μA | 0.02+0.02 | Simulator transmitter: 5-28V power supply outside; 1KΩ at 20mA |
Resistance | 400Ω | 0.00Ω~400.00Ω | 0.01Ω | 0.02+0.02 | Excitation current: ± 0.5-3mA; if ± 0.1-0.5mA, add 0.1Ω; Doesnot include leadresistance |
4KΩ | 0.0000 KΩ~4.0000 KΩ | 0.1Ω | 0.05+0.025 | Excitation current: ± 0.0/mA Does not includelead resistance | |
40kΩ | 0.000 KΩ~40.000 KΩ | 1Ω | 0.1+0.1 | Excitationcurrent: ± 0.01mA; Does not includelead resistance | |
TC | R | 0ºC~1767ºC | 1ºC | 0~100ºC; 1.5ºC 100~1767ºC: 1.2ºC | By using ITS-90 temperature scale; The accuracydoes not include the error of internal temperature compensation caused by a sensor |
S | 0ºC~1767ºC | 0~100ºC : 1.5ºC 100~1767ºC : 1.2ºC | |||
K | -200.0ºC~1372.0ºC | 0.1ºC | -200.0~100.0 : 0.6ºC -100~400.0º : 0.5ºC 400.0~1200.0ºC : 0.7ºC 1200.0~1372.0 : 0.9ºC | ||
E | -200.0ºC~1000.0º | -200~100.0ºC : 0.6ºC -100~600.0ºC : 0.5ºC 600~1000.0ºC : 0.4ºC | |||
TC | J | -200.0º~1200.0ºC |
| -200.0~100.0 : 0.6ºC -100~800.0ºC : 0.5ºC 800~1200.0ºC : 0.7ºC |
|
T | -250.0º~400.0ºC | -250~400.0º : 0.6ºC | |||
N | -200.0ºC~1300.0ºC | -200~100.0ºC : 1.0ºC -100~900.0ºC : 0.7ºC 900~1300.0ºC : 0.8ºC | |||
B | 600ºC~1820ºC | 1ºC | 600~800ºC : 1.5ºC 800~1820ºC : 1.1ºC | ||
L | -200.0º~900.0ºC | 0.1ºC | -200.0~0.0ºC : 0.7ºC 0.0~900.0ºC : 0.5ºC | ||
U | -200.0ºC~600.0ºC | 0.1ºC | -200.0~0.0ºC : 0.7ºC 0.0~600.0ºC : 0.5ºC | ||
RTD | Pt 100 385 | -200.0º~800.0ºC | 0.1ºC | -200.0~0.0ºC : 0.3ºC 0.0~400.0ºC : 0.5ºC 400~800.0ºC : 0.8ºC | By usingtemperature scale ITS-90 Excitation current: ± 0.5~±3mA forPt 100, Cu10, Cu50 add 0.5ºC when excitation current is ± 0.1mA-0.5mA Excitationcurrent: ± 0.05mA~±0.3mA for PT200, PT500, PT1000
Does not include lead resistance |
Pt200 385 | -200.0ºC~630.0ºC | -200~100.0ºC : 0.8ºC100.0~300.0ºC : 0.9ºC 300.0~630.0ºC : 1.0ºC | |||
Pt500 385 | -200.0ºC~630.0ºC | -200~100.0ºC : 0.4ºC100.0~300.0ºC : 0.5ºC 300.0~630.0ºC : 0.7ºC | |||
Pt1000 385 | -200.0ºC~630.0ºC | -200~100.0ºC : 0.2ºC100~300.0ºC : 0.5ºC 300~630.0ºC : 0.7ºC | |||
Cu10 | -100.0ºC~260.0ºC | 1.8ºC | |||
Cu50 | -50.0ºC~150.0ºC | 0.6ºC | |||
FREQ | 100Hz | 1.00Hz~110.00Hz | 0.01Hz | ±2 count | Output voltage: +1-+11V (zero base waveform); Amplitude accuracy: ± 5% reading value + 0.5V; Maximum load: > 100KΩ Duty Cycle : 50% |
1KHz | 0.100KHz~1.100KHz | 1Hz | |||
10KHz | 1.0KHz~11.0KHz | 0.1KHz | |||
100KHz | 10KHz~110KHz | 2KHZ | ± 5 count | ||
PULSE | 100Hz | 1~100000cycles | 1 cyc | ± 2 count | |
1KHz | |||||
10KHz | |||||
SWITCH | 100Hz | 1.00Hz~110.00Hz | 0.01Hz | ± 2 count | Contact output (with 0.0V amplitude setting, FET switch ON/OFF)Maximum open/close voltage/current : + 28V/50mA |
1KHz | 0.100KH~1.100KHz | 1Hz |
| ||
10KHz | 1.0KHz~11.0KHz | 0.1KHz |
| ||
100KHz | 10KHz~110KHz | 2KHz | ± 5 count |
Rating & Reviews
Rating
Similar Products
Metravi
Metravi CAL-400T Universal Calibrator
₹ 10,150
₹ 14,513
Add To Cart
Request Callback
We will get in touch with you
Brand Products
Enter your requirement details!
We will get in touch with you.
Reach Us
-
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034
-
For Support
8920884830
-
Send Us Email
info@insuzo.com
Copyright © 2024. Insuzo
All Rights Reserved.