Kusam Meco KM CAL 905A Multifunction Process Calibrator
Kusam Meco KM CAL 905A Multifunction Process Calibrator
(Based On 10 Reviews)
This multifunction Process Calibrator has high accuracy of ±0.02%. It has 5 digits dual display, Volts, RTD & Thermocouples and it works on 4 x 1.5AAA alkaline battery. Output range up to 500W about 1mA and 5kW about 1.1mA exciting current (for RTD calibration) and output for calibrating R, S, K, E, J, T, N, B type Thermocouple. It also give RTD, PT -100 & Cu 50
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 1,78,499.00
(GST inclusive price) i₹2,31,300.00
( - 23% OFF )
Description
OPTIONAL ACCESSORIES
What's in the box?
|
Rating & Reviews
Rating
Measuring Function | Range | Measuring Range | Resolution | Accuracy | Remark |
DC Voltage | 50mV | -5.000mV ~ 55.000mV | 1mV | 0.02% + 10 | Input impedance: about 100MW |
500mV | -10.00mV ~ 550.00mV | 10mV | 0.02% + 2 | ||
5V | -0.1000V ~ 5.5000V | 0.1mV | 0.02% + 5 | Input impedance:1MW | |
50V | 0.00V ~ 55.00V | 10mV | 0.03% + 5 | ||
DC Current | 50mA | -5.000mA ~ 50.000mA | 1mA | 0.02% + 2 | Input impedance: 10W |
Resistance (Ohm) | 500W about 1mA exciting | 0.00W ~ 550.00W | 0.01W | 0.02% + 0.1W | Plough voltage : about 2.5V not including the accuracy of downlead resistance |
5KW about 0.1mA exciting | 0.0000KW ~ 5.5000KW | 0.1W | 0.02% + 0.5W | ||
Frequency | 100KHz | 2 Hz ~ 110.0 Hz | 0.1Hz | ± 2% | Input impedance:100KW or more,Square wave at least 1Vp-p, 50% duty cycle |
1KHz | 0.100 KHz ~ 1.100 KHz | 1 Hz | |||
10KHz | 0.10 KHz ~ 11.0 KHz | 0.1 KHz | |||
Thermocouple | R | 0 C ~ 1767 C | 1 C | 0~500 C : 1.8 C | Adopt ITS-90 thermometric scale not including the accuracy of inner temperature compensatory error |
S | 0 C ~ 1767 C | 1 C | 500~1767 C : 1.5 C | ||
K | -100 C ~ 1372 C | 0.1 C | -100~0 C : 1.2 C | ||
0~1372 C : 0.8 C | |||||
E | -50 C ~ 1000 C | 0.1 C | -50~0 C : 0.9 C | ||
0~1000 C : 1.5 C | |||||
J | -60 C ~ 1200 C | 0.1 C | -60~0 C : 1.0 C | ||
0~1200 C : 0.7 C | |||||
T | -100 C ~ 400 C | 0.1 C | -100~0 C : 1.0 C | ||
0~400 C : 0.7 C | |||||
N | -200 C ~ 1300 C | 1 C | -200~0 C : 1.5 C | ||
0~1300 C : 0.9 C | |||||
B | 600 C ~ 1820 C | 1 C | 600~800 C : 2.2 C | ||
800~1000 C : 1.8 C | |||||
1000~1820 C : 1.4 C | |||||
MEASURING FUNCTION | |||||
Thermo Resistance | PT 100 | -200 C ~ 800 C | 0.1 C | 200 ~ 0 C:0.5 C | PT100-385 thermometric scale not including the accuracy of down-lead resistance. |
0 ~ 400 C:0.7 C | |||||
400 ~ 850 C:0.8 C | |||||
PT 1000 / PT 200 / PT 500 | -200 C ~ 630 C | 0.1 C | -200 ~ 100 C:0.22 C | ||
100 ~ 300 C:0.3 C | |||||
300 ~ 630 C:0.4 C | |||||
Cu 10 | -100 C ~ 260 C | 0.1 C | 1.8 C | ||
Cu 50 | -50 C ~ 150 C | 50 ~ 150 C:0.7 C | |||
Switch meter measure | About 1mA exciting Current | CLOSE / OPEN | |||
Continuity Test | 500W about 1mA exciting Current | £ 50W | 0.01 C | ||
OUTPUT FUNCTION | |||||
DC Voltage | 100mV | -10.000mV ~ 110.000mV | 1mV | 0.02% + 10 | |
1 V | -0.10000V ~ 1.10000V | 10mV | 0.02% + 10 | Max. Output current 5mA Output Resistance £0.1W | |
10 V | -1.0000V ~ 11.0000V | 0.1mV | 0.02% + 10 | ||
DC Current | 20mA | 0.000mA ~ 22.000mA | 1mA | 0.02% + 10 | Inside power supply 24V 1KW resistance when 20m |
Resistance | 400W | 0.00W ~ 400.00W | 0.01W | 0.02% + 0.1W | ±0.1~3mA exciting current not including the accuracy of down-lead resistanc |
4 KW | 0.0000KW ~ 4.0000KW | 0.1W | 0.05% + 1W | ±0.05~0.3mA exciting current not including the accuracy of down-lead resistance | |
40 KW | 0.000KW ~ 40.000KW | 1W | 0.1% + 10W | ±0.01~0.03mA exciting current not including the accuracy of down-lead resistance | |
Thermocouple | R | 0 C ~ 1767 C | 1 C | 0~100 C:1.5 C | Adopt ITS-90 thermometric scale not including the accuracy of inner temperature compensatory error |
100~1767 C:1.2 C | |||||
S | 0 C ~ 1767 C | 0~100 C:1.5 C | |||
100~1767 C:1.2 C | |||||
K | -200.0 C ~ 1372.0 C | 0.1 C | -200~ -100 C:0.6 C | ||
-100~400 C:0.5 C | |||||
400~1200 C:0.7 C | |||||
1200~1372 C:0.9 C | |||||
E | 200.0 C ~ 1000.0 C | -200~ -100 C:0.6 C | |||
-100~600 C:0.5 C | |||||
-600~1000 C:0.4 C | |||||
J | -200.0 C ~ 1200.0 C | -200~ -100 C:0.6 C | |||
-100~800 C:0.5 C | |||||
800~1200 C:0.7 C | |||||
T | -250.0 C ~ 400.0 C | -250~400 C:0.6 C | |||
N | -200.0 C ~ 1300.0 C | -200~ -100 C:1.0 C | |||
-100~900 C:0.7 C | |||||
900~1300 C:0.8 C | |||||
B | 400 C ~ 1820 C | 1 C | 400~ 600 C:2.0 C | ||
600~800 C:1.5 C | |||||
800~1820 C:1.1 C | |||||
Thermo Resistance | PT 100 | -200.0 C ~ 850.0 C | 0.1 C | -200~0 C:0.3 C | PT100-385 thermometric scale Pt100, Cu50 ±0.1mA excitation current Accuracy does not Include lead resistance. |
0~400 C:0.5 C | |||||
400~850 C:0.8 C | |||||
PT 1000 | -200.0 C ~ 630.0 C | -200~100 C:0.22 C | |||
100~300 C:0.3 C | |||||
300~630 C:0.4 C | |||||
Cu50 | -50.0 C ~ 150.0 C | -50~150 C:0.6 C | |||
Frequency | 100Hz | 1.00Hz ~ 110.00Hz | 0.1Hz | ± 2 | 1~11 Vp-p square wave Accuracy ± 10% 50% duty cycle load>100KW |
1KHz | 0.100KHz ~ 1.100KHz | 1 Hz | |||
10KHz | 1.0KHz ~ 11.0KHz | 0.1 KHz | |||
100KHz | 1KHz ~ 110KHz | 1KHz | |||
Pulse | 100Hz | 10 ~ 100000 Cycles | 1 cyc | ± 2 | 1~11 Vp-p square wave Accuracy ± 10% 50% duty cycle load>100KW |
1KHz | |||||
10KHz | |||||
100KHz | |||||
Switch | 100Hz | 0.1Hz | ± 2 | Max. Switch current voltage/current : + 28 V/50mA | |
1KHz | 1 Hz | ||||
10KHz | 0.1 KHz | ||||
100KHz | 1KHz | ||||
Loop | 24V | ± 10% | Max. Output current about 25mA short circuit protection |
Rating & Reviews
Rating
Similar Products
Request Callback
We will get in touch with you
More From Brands
Enter your requirement details!
We will get in touch with you.
Share This Product
Reach Us
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034