Item(s) Added To Your Bag

Metravi 25 Universal Calibrator

Click To Zoom

Metravi 25 Universal Calibrator

Metravi 25 Universal Calibrator

(Based On 10 Reviews)

50,000 Counts, 0.2% Universal Calibrator for DC Voltage, Current, Resistance, Frequency, all thermocouples and thermo-resistance and for pressure.

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL Products
100% ORIGINAL Products Details

100% ORIGINAL Products

SECURE Payments
SECURE Payments Details

SECURE Payments

₹ 2,69,999.00

(GST inclusive price) i
  • Base Value: ₹ 228812.7
  • GST: (18) % ₹ 41186.3
  • Total Value ₹ 269999

₹3,62,813.00

( - 26% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Measures & Sources: Handles DC Voltage, Current, Resistance, and Frequency.
  • Wide Thermocouple Support: Works with R, S, K, E, J, T, N, B types.
  • RTD Calibration: Supports various PT and Cu RTD types
  • Pressure Ready: Connects to a pressure module for calibration.
  • Simultaneous Operation: Measures and sources at the same time.
  • High Accuracy: Very precise, with ±0.02% accuracy for DC signals. 
  • Clear Display: 50,000 counts, dual, backlit display. 
  • Data Hold: Freezes readings for easy viewing. 
  • Safety Compliant: Meets IEC 61010 safety standards. 
  • 24V Loop Power: Provides power for industrial devices.

 

What's in the box?

  • Metravi 25 Universal Calibrator
  • Two set of Industrial testing Lead 
  • A set of Testing Lead 
  • A set of Alligator clip 
  • A quick reference guide 
  • A User's Manual 
  • One Fuse 50mA/250V 
  • One Fuse 63mA/250V

 

 

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image

Product Specifications

GENERAL 

FunctionReference Range Resolution Accuracy Remark 
DCV50mV - 5.000mV ∼ 55mV 1μν 0.02 +0.02 Input Resistance: 100ΜΩ 
500mV - 50mV ∼ 550mV 10μν 0.02 +0.01
5V - 0.5V ∼ 5.5V 0.1mV 0.02 +0.01Input Resistance: 1ΜΩ 
50V -5.000V ∼ 55V 1mV 0.03 +0.01 
DCmA 50mA 
 
5.000mA ∼ 55mA 1μΑ 0.02 +0.01Shunt Resistance: 100
OHM 500Ω Test Current: Approximately 1mA0.00Ω ∼ 550.00Ω0.01Ω0.05 +0.02 
 
Open Circuit Voltage:about 2.5V; Does not include lead resistance
5ΚΩ Test Current Approximately 0.1mA 0.0000 ΚΩ~5.5000ΚΩ 0.1Ω0.05 +0.02 
FREQ 500Hz 3Hz-500.00Hz 0.01Hz ± 2digit Input Impedance: 100 k2 at least; Sensitivity: 3Vp-p minimum Duty Cycle: 50%.
5KHz 3Hz - 5KHz 0.1Hz 
50KHz 3Hz - 50KHz 1Hz 
TCR0°C - 1767°C1°C

0-500°C: 1.8°C 

500-1767:1.5 

By using ITS-90 temperature scale; The accuracy does not include the error of internal temperature compensation caused by a sensor, 
S0°C - 1767°C
K-100.0°C ∼ 1372.0°C0.1°C-100.0~0°: C1.2°C, 0 ~1372 °C / 0.8 
E-50.0°C ∼ 1000.0°C -50.0°C 0°C: 0.9°C, 0~1000.0°C: 1.5°C 
 J-60.0°C ∼ 1200.0°C-60.0-0°C: 1.0°C, 0~1200.0°C: 0.7°C 
T-100.0°C ∼ 400.0°C-100.0~0 ^ o * C / (1 ^ o) * C , 0~400.0°C: 0.7°C 
N-200.0°C ∼ 1300.0°C-200.0-0°C: 1.5°C, 0~1300.0°C: 0.9°C 
B600°C ∼ 1300.0°C1°C600~800°C: 2.2°C, 800 ~1000 °C  1.8°C, 1000-1820°C: 1.4°C 
RTD Pt100-385 - 200.0°C - 800.0°C0.01°C200.0 ~0 °C  0.5°C 0 ~400 °C  : 0.7°C 
400.0-800.0°C: 0.8°C 
By using Pt100-385 Does not include lead resistance
 Pt1000-385 - 200.0°C - 630.0°C -200.0~100.0°C: 0.3°C, 100.0-300.0°C: 0.5°C, 300.0°C-630.0°C: 0.7°C 
 P1200-385 - 200.0°C - 630.0°C200.0 ~100 °C  : 0.8°C, 100.0 ~300 °C  : 0.9°C, 300.0-630.0°C: 1.0°C 
 P1500-385 - 200.0°C - 630.0°C-200.0 ~100 °C: 0.4°C, 100.0-300.0°C: 0.5°C, 300.0-630.0°C: 0.7°C 
 Cu10 - 100.0°C - 260.0°C1.8°C 
 Cu50 - 50.0°C - 150.0°C0.7°C 
SWITCH  CLOSE/OPEN   Approximately 1mA Test Curren Short circuit display: CLOSE, Open circuit display: OPEN; Threshold value about 200~3000 
CONT. 500Ω=500 sound   Approximately 1mA Test Current 

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image