Key Features

  • Here are 10 key features of the Kusam Meco KM CAL-802 in 5 words:
  • Source and measure thermocouples.
  • Supports multiple thermocouple types.
  • Outputs and measures DC voltage.
  • High accuracy: ±0.05%.
  • Clear 5-digit LCD display.
  • Ambient temperature compensated.
  • Robust, portable design.
  • ITS-90 standard compliant.
  • IEC 1010 safety compliant.
  • Battery-powered for field use.

 

What's in the box?

  • Kusam Meco KM CAL 802 Digital Voltage Tester
  • User Manual
  • Test lead CF-36
  • Clips for probe
  • Holster
  • Carrying case.

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image

Product Specifications

GENERAL

Basic Accuracy : ± 0.05%
Display : 5 Digit LCD display.
Max. Allowable Voltage : 30V.
Operating Temperature Range : 0 ~ 50°C.
Humidity range : = 80% RH
Storage Temperature Range : ≤ -10°C ~ 55°C
Humidity range : ≤ 90% RH
Temperature Coefficient : 0.1 x (dedicated Accuracy) %
  /°C (5°C ~ 18°C, 28°C ~ 40°C)
Power Consumption : about 50m / 3V.
Dimension : 180 (L) x 90 (W) x 47 (D) mm (with protector)
Weight : About 500g.

 

TECHNICAL

OutputRangeOutput RangeResolutionAccuracyRemarks
DC Voltage100mV-10.00 ~ 110.00mV0.01mV±0.05% ± 30μVThe max. Output current ± 2mA
1V-0.1000 ~ 1.1000V0.1mV±0.05% ± 30mV
ThermocoupleR-40 ~ 1760 C1 C±0.05% + 3(Less than or equals to 100 C) O ±0.05% + 2(more than 100 C)Employs ITS-90 temperature standard The accuracy does not include the error of interior temperature compensation sensor The accuracy does not include the impact of interior thermoelectric force.
S-20 ~ 1760 C1 C
RTDB400 ~ 1800 C1 C±0.05% + 3(Less than or equals to 600 C) O ±0.05% + 2(more than 600 C)
E-200.0 ~ 1000.0 C0.1 C±0.05% + 20 (Less than or equals to -100 C) O ±0.05% + 10 (more than -100 C)
K-200.0 ~ 1370 C0.1 C
 J-200.0 ~ 1200.0 C0.1 C
T-200.0 ~ 400.0 C0.1 C
N200.0 ~ 1300.0 C0.1 C
OutputRangeOutput RangeResolutionAccuracyRemarks
DC Voltage100mV-10.00 ~ 110.00mV0.01mV±0.05% ± 3Input Resistance : 1MΩ 

Thermocouple

RTD

R-40 ~ 1760 C1 C±0.05% + 3(Less than or equals to 100 C) O ±0.05% + 2(more than 100 C)

Input Resistance : 1MΩ

Employs ITS-90 temperature standard The accuracy does not include the error of interior temperature compensation sensor The accuracy does not include the impact of interior thermoelectric force

S-200 ~ 1760 C1 C
B400 ~ 1800 C1 C±0.05% + 3(Less than or equals to 600 C) O ±0.05% + 2(more than 600 C)
E-200.0 ~ 1000.0 C0.1 C±0.05% + 20 (Less than or equals to -100 C) ±0.05% + 10 (more than -100 C)
K200.0 ~ 1370 C0.1 C
 J-200.0 ~ 1200.0 C0.1 C
T200.0 ~ 400.0 C0.1 C
N-200.0 ~ 1300.0 C0.1 C

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image