Kusam Meco M3500A Bench Type Digital Multimeter 2000 Rdgs
Kusam Meco M3500A Bench Type Digital Multimeter 2000 Rdgs
(Based On 10 Reviews)
The Kusam-Meco M3500A is a high-precision 6.5-digit digital multimeter designed for laboratory and industrial applications. With a 200,000-count resolution, it offers accurate measurements across 11 functions and 25 ranges, including DC/AC voltage, current, resistance, frequency, period, diode, and temperature (via thermocouple and RTD). Its dual 5×7 dot matrix VFD display with three-color annunciators ensures clear readings.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 1,40,199.00
(GST inclusive price) i₹1,81,699.00
( - 23% OFF )
Description
OPTIONAL ACCESSORIES
What's in the box?
|
Rating & Reviews
Rating
• Sensing :True RMS Sensing
• High Accuracy : DC Voltage : ± 0.0035% of reading. AC Voltage : ± 0.06% of reading.
• Resolution : 6½ digit 2,00,000 Counts
• Display : 5 x 7 dot matrix VFD, Dual displays with three-color annunciators.
• High Speed : Both sampling rate and data rate are at 2000 readings/sec (at 4½ digit setting).
• High Capacity of Internal Data Memory : It can store up to 2000 readings in data memory
• Full-Featured Operations : There are 11 measurements and 8 math Functions.
• Temperature Measurements : The built-in function supports two measurement methods : Thermocouples and RTDs. For thermocouples, it supports up to 7 types of sensors E, J, K, N, R, S and T.
• Data Transfer rate : 2000 readings/Sec.
• Vibration : MIL-PRF-28800F, 3.84.2. Vibration, Sinusoidal Class 1.2
• Shock : Mil-prf-28800f, 4.5.5.4 Mechanical.± (%of reading + %of range,23 °C ± 5 °C) at 6 ½ digits with 2-hour warm-up.
• Bandwidth : 3Hz. Specifications are for sine wave input >5% of range. For <50KHz & inputs within 1% to 5% of range, the error 0.3% of range must be added. For inputs within 50KHz to 100KHz, the 0.35% of range must be added.
• Power Line Frequency : 50/60Hz ± 10%
• Power Consumption : 25VA Max. (16W Average)
• Operating Temperature : 0°C ~ 50°C; 80% R.H. Upto 31°C.
• Storage Temperature : -40°C ~ 70°C
• Operating Altitude : upto 2000M
• Power Supply : 100V/120V/220V/240V±10%
• Dimension : 213.6(W) x 88.6(H) x 370.0(D)mm
• Weight : approx. 2.23Kg.
DC VOLTAGE | |||
Function | Range | Input Resistance | 1 Year Accuracy : ± (% of reading + % of range ) o o (23 C ± 1 C) |
DCV (DC Voltage) | 100.0000 mV | > 10G | 0.0050 + 0.0035 |
1.000000 V | > 10G | 0.0040 + 0.0007 | |
10.00000 V | > 10G | 0.0035 + 0.0005 | |
100.0000 V | 10 M | 0.0045 + 0.0006 | |
1000.000 V | 10 M | 0.0045 + 0.0010 |
DC CURRENT | |||
Function | Range | Shunt Resistance | 1 Year Accuracy : ± (% of reading + % of range ) o o (23 C ± 1 C) |
DCV (DC CURRENT) | 10.00000 mA | 5.1 | 0.050 + 0.020 |
100.0000 mA | 5.1 | 0.050 + 0.005 | |
1.000000 A | 0.1 | 0.100 + 0.010 | |
3.00000 A | 0.1 | 0.120 + 0.020 |
AC CHARACTERISTICS | |||
Function | Range | Frequency (Hz) | 1 Year Accuracy : ± (% of reading + % of range ) o o (23 C ± 1 C) |
ACV (AC TRMS Voltage) | 100.0000 mV | 3 - 5 | 1.00 + 0.04 |
5 - 10 | 0.35 + 0.04 | ||
10 - 20 K | 0.06 + 0.04 | ||
20K - 50 K | 0.12 + 0.05 | ||
50K - 100K | 0.60 + 0.08 | ||
100K - 300K | 4.00 + 0.50 | ||
1.000000 V to 750.000V | 3 - 5 | 1.00 + 0.03 | |
5 - 10 | 0.35 + 0.03 | ||
10 - 20 K | 0.06 + 0.03 | ||
20K - 50 K | 0.12 + 0.05 | ||
50K - 100K | 0.60 + 0.08 | ||
100K - 300K | 4.00 + 0.50 | ||
ACA (AC TRMS Current) | 1.000000 A | 3 - 5 | 1.00 + 0.04 |
5 - 10 | 0.30 + 0.04 | ||
10 - 5 K | 0.10 + 0.04 | ||
3.00000 A | 3 - 5 | 1.10 + 0.06 | |
5 - 10 | 0.35 + 0.06 | ||
10 - 5 K | 0.15 + 0.06 |
RESISTANCE | |||
Function | Range | Frequency (Hz) | 1 Year Accuracy : ± (% of reading + % of range ) o o (23 C ± 1 C) |
Resistance (Specifications are for 4W or 2W when a NULL operation is used). | 100.0000 | 1 mA | 0.010 + 0.004 |
1.000000 K | 1 mA | 0.010 + 0.001 | |
10.00000 K | 100 A | 0.010 + 0.001 | |
100.0000 K | 10 A | 0.010 + 0.001 | |
1.000000 M | 5 A | 0.010 + 0.001 | |
10.00000 M | 500 nA | 0.040 + 0.001 | |
100.0000 M | 500 nA/ 10 M | 0.800 + 0.010 | |
Diode Test | 1.00000 V | 1 mA | 0.010 + 0.020 |
Continuity | 1000.00 | 1 mA | 0.010 + 0.030 |
FREQUENCY AND PERIOD | |||
Function | Range | Frequency (Hz) | 1 Year Accuracy : ± (% of reading + % of range ) o o (23 C ± 1 C) |
Frequency & Period | 100 mV to 750 V | 3 - 5 | 0.10 |
5 - 10 | 0.05 | ||
10 - 40 | 0.03 | ||
40 - 300K | 0.01 |
Rating & Reviews
Rating
Similar Products
Request Callback
We will get in touch with you
More From Brands
Enter your requirement details!
We will get in touch with you.
Share This Product
Reach Us
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034
For Support
8920884830
Send Us Email
info@insuzo.com
Copyright © 2024. Insuzo
All Rights Reserved.