Metravi PM-39 Process Meter
Metravi PM-39 Process Meter
(Based On 10 Reviews)
5 Digits, Digital Multimeter combined with source for DC voltage, resistance, frequency, thermocouples, thermal resistance, and DC current. supply power to 24V circuits and meanwhile measure current; with built-in250 Ω HART loop resistance
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 51,999.00
(GST inclusive price) i₹69,863.00
( - 26% OFF )
Description
What's in the box?
|
Rating & Reviews
Rating
Display | Digit: 4-digit display (for current measurement and output: 5-digit display) |
Display refreshing | Fast (F): 20 times/second; slow (S): 5 times/second |
Temperature and humidity range for work | 0 ~ 40 ºC, relative humidity ≤85% (without moisture condensation) |
Temperature and humidity range for storage | -20 ºC ~ 60 ºC, relative humidity below 90% (without moisture condensation) |
Temperature and humidity range for guaranteed precision | 23 ± 5ºC, relative humidity below 75% (without moisture condensation) |
Temperature factor | 0.1× basic precision / °C (temperature range: <18°C or >28°C) |
Application environment | Indoors, outdoors (non-watertight), altitude of 0 ~ 2000m |
Indication of outrange | OL |
On-Off / open-circuit test | Buzzer beeps indicate the resistance reading is lower than the threshold, or an open circuit |
Battery type | Four 1.5V (LR6) alkaline batteries |
Service life of batteries | When alkaline batteries are used, For measurement of all parameters: about 100 hours For DC current output (SIMULATE): about 50 hours For DC current output (SOURCE) 20mA (load of 1000Ω): about 2.5 hours |
Low battery indication | It is indicated with a battery mark. |
Automatic shutdown | The meter is automatically shut down after about 5 minutes of no operation. The time can be adjusted. |
Warm-up time | 10 minutes |
Close meter calibration | No need for internal adjustment |
Battery cover | For battery replacement, without influencing meter calibration |
Size | 206 (L)×97 (W)×60 (D)mm |
Weight | About 500g |
Function | Range | Measuring scope | Resolution | Precision |
DC voltage DCV | 50m | -55.00mV ~ 55.00mV | 0.01mV | 0.1%+4 |
500mV | -550.0mV ~ 550.0mV | 0.1mV | 0.1%+4 | |
5V | -5.500V ~ 5.500V | 0.001V | 0.1%+4 | |
50V | -55.00V ~ 55.00V | 0.01V | 0.1%+4 | |
500V | -550.0V ~ 550.0V | 0.1V | 0.1%+4 | |
1000V | -1000V ~ 1000V | 1V | 0.1%+4 | |
AC voltage ACV | 5V | 0 ~ 5.500V | 0.001V | 0.5%+4(<400Hz) 5%+4(>400Hz) |
50V | 0 ~ 55.00V | 0.01V | 0.5%+4 | |
500V | 0 ~ 550.0V | 0.1V | 0.5%+4 | |
1000V | 0V ~ 750V | 1V | 0.5%+4 | |
OHM ( Ω ) | 500Ω | 0 ~ 550.0Ω | 0.1Ω | 0.1%+4 |
5KΩ | 0 ~ 5.500KΩ | 0.001KΩ | 0.1%+4 | |
50KΩ | 0 ~ 55.00KΩ | 0.01KΩ | 0.1%+4 | |
500KΩ | 0 ~ 550.0KΩ | 0.1KΩ | 0.5%+4 | |
5MΩ | 0 ~ 5.500 MΩ | 0.001MΩ | 1%+4 | |
50MΩ | 0 ~ 55.00 MΩ | 0.01MΩ | 1%+4 | |
DC current DCI | 50mA | -55.000mA ~ 55.000mA | 0.001mA | 0.1%+5 |
500mA | -500.00mA ~ 500.00mA | 0.01mA | 0.1%+5 | |
AC current ACI | 50mA | 0000mA ~ 55.000mA | 0.001mA | 0.5%+10 |
500mA | 0.00mA ~ 500.00mA | 0.01mA | 0.5%+10 | |
Frequency FREQ | 10Hz | 0 ~ 9.9999Hz | 0.0001Hz | 0.02%+4 |
100Hz | 0 ~ 99.999Hz | 0.001Hz | 0.02%+4 | |
1000Hz | 0 ~ 999.99Hz | 0.01Hz | 0.02%+4 | |
10kHz | 0 ~ 9.9999kHz | 0.0001kHz | 0.02%+4 | |
100kHz | 0 ~ 99.999kHz | 0.001kHz | 0.02%+4 | |
DUTY | 10% ~ 90% | 0.1% | 1% | |
Diode | 2V | 0.001V | 1%+10 | |
On-off test | 500Ω | 0.1Ω | ≤50ΩBB |
Thermocouple TC | R | -40°C ~ 1760°C | 1°C | 0.5%+3°C (≤100) °C 0.5%+2°C(>100) °C |
S | -200°C ~ 1760°C | |||
B | 400°C ~ 1800°C | |||
K | -200°C ~ 1350°C | 0.5%+2°C (≤-100) °C 0.5%+1°C (>-100) °C | ||
E | -200°C ~ 700°C | |||
J | -200°C ~ 950°C | |||
T | -200°C ~ 400°C | |||
N | -200°C ~ 1300°C | |||
Thermal resistance RTD | Cu50 | -50°C ~ 150°C | 1°C | 0.5%+3°C |
Pt100 | -200°C ~ 850°C | |||
Capacitance CAP | 10nF | 0 ~ 11.00nF | 0.01nF | 5%+50 |
100nF | 0 ~ 110.0nF | 0.1nF | 5%+5 | |
1000nF | 0 ~ 1100nF | 1nF | 5%+5 | |
10µF | 0 ~ 11.00µF | 0.01uF | 5%+5 | |
100µF | 0 ~ 110.0µF | 0.1uF | 5%+5 | |
1000µF | 0 ~ 1100µF | 1uF | 5%+5 | |
10mF | 0 ~ 11.00mF | 0.01mF | 5%+50 | |
100mF | 0 ~ 110.0mF | 0.1mF | 5%+50 |
Function | Range | Output setting scope | Resolution | Precision | Remark |
DC voltage DCV | 100mV | -10.00 ~ 110.00mV | 10μV | 0.2%+4 | Maximum output current 0.5mA |
1000mV | -100.0 ~ 1100.0mV | 100μV | 0.2%+4 | Maximum output current 2mA | |
10V | -1.000 ~ 11.000V | 1mV | 0.2%+4 | Maximum output current 5mA | |
DC current DCI | 30mA | 0.000 ~ 33.000mA | 0.001mA | 0.2%+4 | 20mA, maximum load1KΩ 30mA, maximum load600Ω |
Simulated transmitter SIMULATE | -30mA | 0.000 ~ -33.000mA | 0.001mA | ||
Loop power LOOP | 24V | ±10% | Maximum output current 35mA | ||
OHM | 400Ω | 0.0Ω ~ 400.0Ω | 0.1Ω | 0.2%+4 | Excitation current: ±0.5 ~ 3mA When excitation current is ±0.1 ~ 0.5mA, an additional error of 0.1Ω should be taken into account. The precision doesn’t include lead resistance. |
Thermocouple TC | R | 0°C ~ 1767°C | 1°C | 0.2%+3°C (≤100) 0.2%+2°C (>-100) | With the thermometric scale of ITS-90; The precision doesn’t include errors in cold-end compensation |
S | 0°C ~ 1767°C | ||||
B | 600°C ~ 1820°C | ||||
K | -200.0°C ~ 1372.0°C | 0.1°C | 0.2%+2°C (≤-100) 0.2%+1°C (>-100) | ||
E | -200.0°C ~ 1000.0°C | ||||
J | -200.0°C ~ 1200.0°C | ||||
T | -250.0°C ~ 400.0°C | ||||
N | -200.0°C ~ 1300.0°C | ||||
Thermal resistance RTD | PT100 | -0200.0 ~ 0850.0 | 0.1°C | 0.2%+0.6°C | With the thermometric scale of Pt100-385; With excitation current of ±1mA The precision doesn’t include lead resistance. |
Cu50 | -050.0 ~ 150.0 | ||||
Frequency FREQ | 100Hz | 1.0Hz ~ 110.0Hz | 0.1Hz | 0.2%+2 | Rectangular wave, duty cycle of 50% 1 ~ 11Vp-p |
1KHz | 0.100KHz ~ 1.100KHz | 1Hz | 0.2%+2 | ||
10KHz | 1.0KHz ~ 11.0KHz | 0.1KHz | 0.2%+2 |
Function position | Input impedance (nominal value) | |||||
V | 10MΩ, <100pF | |||||
mV | >2.5GΩ | |||||
Common-mode rejection ratio | Series-mode rejection ratio | |||||
DCV, DCmV | 80dB (dc to 50Hz / 60Hz/1KΩ) | 40dB (50Hz / 60Hz) | ||||
ACV, ACmV | 60dB (dc to 50Hz / 60Hz/1KΩ) | |||||
Open-circuit voltage | Full-scale voltage | |||||
Ohm | 2.5V | 2.2V | ||||
Diode | < 3.5V | 2.2V | ||||
On-off | < 1V | 500mV | ||||
Typical short-circuit current | ||||||
Ohm | 500Ω | 5KΩ | 50KΩ | 500KΩ | 5MΩ | 50MΩ |
0.8mA | 0.2mA | 20μA | 2μA | 0.2μA | < 0.1μA | |
Diode | 0.2mA (typical value) |
Rating & Reviews
Rating
Request Callback
We will get in touch with you
More From Brands
Enter your requirement details!
We will get in touch with you.
Share This Product
Reach Us
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034
For Support
8920884830
Send Us Email
info@insuzo.com
Copyright © 2024. Insuzo
All Rights Reserved.