Metravi CAL-400 mV mA Calibrator
Metravi CAL-400 mV mA Calibrator
Metravi CAL-400 mV mA Calibrator
(Based On 10 Reviews)
mV mA Calibrator for Measuring and Source of 100mV / 30V DC Voltage, 20mA DC Current and switching value measurements. Supports manual Step Output, Automatic Waveform Output, and allows for simultaneous display of Voltage (V), Current (mA), and percentage. Loop detection function, overload protection.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL PRODUCTS
SECURE PAYMENTS
1 YEAR WARRANTY
AUTHORIZED DISTRIBUTOR
B2B INVOICES
₹ 9,062
(GST inclusive price) i-
Base Value: ₹ 7679.7
-
GST: (18) % ₹ 1382.3
-
Total Value ₹ 9062
₹12,960.00
( - 30% OFF )
Description
Key Features
- The Metravi CAL-400 is a versatile and precise mV/mA Calibrator, designed to meet the needs of professionals in testing, calibration, and troubleshooting applications.
- With its wide range of functions, this device offers 100mV / 30V DC Voltage measurement, 20mA DC Current measurement, and switching value measurement, ensuring high accuracy and reliability.
- In addition to measurement capabilities, the Metravi CAL-400 provides 100mV / 30V DC Voltage Output, 20mA DC Current output, and SIMULATE output, making it a powerful tool for calibration tasks.
- It supports manual Step Output, Automatic Waveform Output, and allows for simultaneous display of Voltage (V), Current (mA), and percentage, offering enhanced usability and efficiency.
- Equipped with a loop detection function, the calibrator can simultaneously provide a 24V Loop Power supply while measuring Current, making it ideal for loop testing in process control applications.
- With built-in overload protection, the Metravi CAL-400 ensures safety and durability, making it a must-have tool for professionals in industries such as instrumentation, automation, and maintenance.
What's in the box?
|
Rating & Reviews
Rating
GENERAL
| Sampling Time | 2-3 times / second |
| Overload Protection | 50mA/30V |
| Working Environment | 0° ~ 40°C ; below 85% RH (no condensation) |
| Storage Environment | -20° ~ 60°C ; below 90% RH (no condensation) |
| Accuracy Defined as per Environment | 23°±5°C ; below 75% RH (no condensation) |
| Temperature Coefficient | 0.1 × basic precision / °C (temperature range <18°C or >28°C) |
| Ambient Condition for Usage | Indoor and outdoor use (not waterproof),with an elevation of 0~2000 m |
| Overrange Display | OL |
| Power Source | 3 x 1.5V ( LR03/AAA ) Alkaline Batteries |
| Power Consumption | When alkaline battery is used Loop current measurement and DC current output (SOURCE) 20mA (a load of 1000Ω): approx. 1000m |
| Low Battery Indication | Shows battery sign |
| Auto Shutdown | After 15 min of non-operation |
| Warm-up Time | 10 mins |
| Dimensions | 151 x 75 x 42 mm |
| Weight | Approx. 230 gms |
| Calibration Cycle | One year |
TECHNICAL
| MEASUREMENT | |||||
| Range | Measuring Range | Resolution | Accuracy | Notes | |
| DC Voltage | 100mV | -10.0mV~110.0mV | 100uV | 0.2%+4 | • Input impedance: 30V: 300kΩ (nominal value) mV:>1MΩ (nominal value) • Common mode rejection: 50Hz or 60Hz >80dB • Series mode rejection: 50Hz or 60Hz > 40dB • Overvoltage protection:30V (peak to peak value) |
| 30V | -5.00V~30.00V | 10mV | |||
| DC Current | 20mA | 0.00mA~22.00mA | 0.01mA | • Overload protection: 50mA/30V • Load voltage: approx. 18mV/mA | |
| OUTPUT | |||||
| Range | Output Setting Range | Resolution | Accuracy | Notes | |
| DC Voltage | 100mV | 0.0mV~110.0mV | 100uV | 0.2%+4 | • Maximum output current 1mA |
| 10V | 0.00V~11.00V | 10mV | • Maximum output current 5 mA (<10V) | ||
| DC Current | 20mA | 0.00mA~22.00mA | 0.01mA | • 20mA maximum load 1kΩ | |
| Analogue Transmitter SIMULATE | -20mA | 0.00mA~22.00mA | 0.01mA | • External power supply: 5 〜 28V • 20mA maximum load 1kΩ | |
| Loop Power Supply LOOP | 24V | ±10% | • Maximum output current 25mA | ||
Rating & Reviews
Rating
Similar Products
Request Callback
We will get in touch with you
Brand Products
Enter your requirement details!
We will get in touch with you.
Reach Us
-
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034
-
For Support
8920884830
-
Send Us Email
info@insuzo.com
Copyright © 2024. Insuzo
All Rights Reserved.