Item(s) Added To Your Bag
Metravi M-45 Bench-type Digital Multimeter
Metravi M-45 Bench-type Digital Multimeter
5 digits, 55000 Counts, bench-type, compact, T-RMS Multimeter with large TFT Colour Display, USB & RS232 Interfaces for Data Logging & Analysis. Supports Dual line display & SCPI. Measure Voltage, Current, Resistance, Capacitance, Frequency, RTD/K-type Temperature.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 12,399.00
(GST inclusive price) i₹16,706.00
( - 26% OFF )
Description
What's in the box?
|
Display | 3.5-inch TFT LCD with resolution 480*320 |
Data Logging | Auto/Manual Mode, 1000 data |
Safety Certifications | CATI 1000V, CATII 600V |
Accessories | Test Leads, Crocodile Clips, Power Cord, Spare Fuse |
Operating Environment | Full temperature from 0°C to 50°C, ≤80% RH and 40°C non-condensing |
Storage Environment | Storage Temperature: -20°C to 70°C, ≤80%RH |
Remote Interface | USB Device |
Programmer Language | Standard SCPI, compatible with commands of main stream multimeters |
Warm-up Time | 30 minutes |
Dimensions | (W×H×D) 200 x 86.5 x 64 mm |
Weight | 0.45 kgs |
Temperature | K type, Pt100 |
Display | 55,000 |
Record Interval | 15 mS - 9999.999 S |
Record Length | 1,000 points |
DC CURRENT | ||
Range | Resolution | Accuracy: ± (% of reading + LSB) |
500 uA | 0.01 uA | ±0.15% + 20 |
5000 uA | 0.1 uA | ±0.15% + 10 |
50 mA | 0.001 mA | ±0.15% + 20 |
500 mA | 0.01 mA | ±0.15% + 10 |
5 A | 0.0001 A | ±0.5% + 10 |
10 A | 0.001 A | ±0.5% + 10 |
TRUE RMS AC CURRENT | ||
Range | Resolution | Accuracy: ± (% of reading + LSB) |
500 uA -500 mA | 20 Hz-1 kHz | ±0.5% + 20 |
5A-10A | ±1.5% + 20 |
DC VOLTAGE | ||
Range | Resolution | Accuracy: ± (% of reading + LSB) |
50.000 mV | 0.001 mV | ±0.1%+10 |
500.00 mV | 0.01 mV | ±0.025% + 5 |
5.0000 V | 0.0001 V | ±0.025% + 5 |
50.000 V | 0.001 V | ±0.03% + 5 |
500.00 V | 0.01 V | ±0.1% + 5 |
1000.0 V | 0.01 V | ±0.1%+5 |
TRUE RMS AC VOLTAGE | ||
Range | Resolution | Accuracy: ± (% of reading + LSB) |
500 mV- 750V | 20 Hz- 45 Hz | ±1%+30 |
45 Hz- 65 Hz | ±0.5%+30 | |
65 Hz- 1kHz | ±0.7%+30 |
RESISTANCE | ||
Range | Resolution | Accuracy: ± (% of reading + LSB) |
500 Ω | 0.01 Ω | ±0.1%+10 |
5 kΩ | 0.0001 kΩ | ±0.1%+5 |
50 kΩ | 0.001 kΩ | ±0.1%+5 |
500 kΩ | 0.01 kΩ | ±0.1%+5 |
5 MΩ | 0.0001 MΩ | ±0.25% + 5 |
50 MΩ | 0.01 MΩ | ±1%+10 |
CAPACITANCE | |
Range | Accuracy: ± (% of reading + LSB) |
50 nF - 500 uF | ±2.5%+5 |
5 mF - 50 mF | ±5%+8 |
FREQUENCY | |
Range | Accuracy: ± (% of reading + LSB) |
10.000 Hz - 60 MHz | ± (0.2%+8) |
CONTINUITY | |
Range | Resolution |
1000 Ω | 0.1 Ω |
Similar Products
Request Callback
We will get in touch with you
More From Brands
Enter your requirement details!
We will get in touch with you.