4 Digits, Dual LCD, Harmonic Analysis up to 50th Harmonic, PC Interface, Single Phase & Three Phase, Maximum Demand, KW, KVA, KVAR, KWh, KVAh, KVArH, Power Factor, Real time output of waveform, Power Parameters and Harmonics. Clamp Jaw Size – 55mm.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 1,06,313.00
(GST inclusive price) i₹1,06,313.00
( - 0% OFF )
Description
What's in the box?
|
Rating & Reviews
Rating
General Specification | |
Conductor Size | 55mm(approx.),64*24mm(bus bar) |
Battery Type | two 1.5 V SUM-3 |
Display | 128*64 Dot Matrix |
Power Consumption | 10 mA(approx) |
Auto - Power - Off | 30 minutes after power-on |
Update time | 2 times/sec.(display) |
No. of Sameples per Period | 512(voltage or current), 256(power) |
Operating Temperature | -10 °C to 50 °C |
Operating Humidity | <85% RH |
Storage temperature | -20 °C to 60 °C |
Storage Humidity | <75% RH |
Dimension | 210 mm (L) x 62 mm (W) x 35.6 mm (H),8.3" (L) x 2.5 "(W) 1.4" (H) |
Weight | test leads 1 pair, Carrying bag 1, Users manual 1, Batteriews 1.5V 2 |
Technical Specification | ||
AC Current (50 or 60 Hz, Auto Range, True RMS) | ||
Range | Resolution | Accuracy |
4.0V - 1500.0A4.0V - 1500.0A | 0.01A | ± 0.5% ± 5 dgts |
AC Voltage t (50 or 60 Hz, Auto Range, True RMS) | ||
Range | Resolution | Accuracy |
4.0V - 1500.0A | 0.01V | ± 0.5% ± 5 dgts |
Harmonics of AC Voltage in Percentage and Magnitude (1 to 50th order) | |||
Range | Resolution | Accuracy (in%) | Accuracy (in Magnitude) Magnitude) |
1-20th | 0.1% | ±2 | ± 2% ± 0.5V |
20-50th | 0.1% | ± 4% or reading ± 2 | ± 4% or reading ± 5% |
Harmonics of AC Current in Percentage and Magnitude (1 to 50th order) | |||
Range | Resolution | Accuracy (in%) | Accuracy (in Magnitude |
1-20th 0.1 | 0.1% | ±2 | ± 2% of reading ± 0.4A |
20-50th | 0.1% | (± 4)% or reading (± 2)% | (± 4)% or reading ± 0 % Power Factor (PF) |
Power Factor (PF) | ||
Range | Resolution | Accuracy |
0.000-1.000 | 0.001 | ± 0.04 |
Phase Angle (>) | ||
Range | Resolution | Accuracy |
- 180 deg to 180 deg 0 deg 360 deg ) | 0.1 ^ 0 | ± 1 deg |
Total Harmonic Distortion (%THD-F, 1 to 50th order) | ||
Range | Resolution | Accuracy |
0 + (- 20)% | 0.1% | ± 2% |
20 + (- 100)% | 0.1% | ±6% of reading ± 1% |
100 + (- 999.9)% | 0.1% | (plus/minus 10)% of reading (plus/minus 1)% |
Crest Factor (C.F.) | ||
Range | Resolution | Accuracy |
1.00-99.99 | 0.01 | (± 5)% ±30 digits |
AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1) | ||
Range | Resolution | Accuracy |
10.0-999.9W | 0.1W | ±1% ± 20 dgts |
1.00-9.999 KW | 0.001 KW | ± 1% ± 20 dgts |
10.00-99.99KW | 0.01KW | ± 1% ± 20 dgts |
100.0-99.9KW | 0.1KW | ± 1% ± 20 dgts |
1000-9999KW | 1KW | ± 1% ± 20 dgts |