Item(s) Added To Your Bag

Kusam Meco KM CAL 802 Digital Voltage Tester

Click To Zoom

Kusam Meco KM CAL 802 Digital Voltage Tester

Kusam Meco KM CAL 802 Digital Voltage Tester

(Based On 10 Reviews)

This is a Thermocouple “Source” &”Sink” Calibrator. It gives output of DC Volts & output for R, S, B, E, K, J, T & N Thermocouples. It measures DC Voltage & also R, S, B, E, K, J, T & N Thermocouples. It has 5 digit LCD display & extremely high accuracy 0.05%.

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL Products
100% ORIGINAL Products Details

100% ORIGINAL Products

SECURE Payments
SECURE Payments Details

SECURE Payments

₹ 23,199.00

(GST inclusive price) i
  • Base Value: ₹ 19660.2
  • GST: (18) % ₹ 3538.8
  • Total Value ₹ 23199

₹30,000.00

( - 23% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Here are 10 key features of the Kusam Meco KM CAL-802 in 5 words:
  • Source and measure thermocouples.
  • Supports multiple thermocouple types.
  • Outputs and measures DC voltage.
  • High accuracy: ±0.05%.
  • Clear 5-digit LCD display.
  • Ambient temperature compensated.
  • Robust, portable design.
  • ITS-90 standard compliant.
  • IEC 1010 safety compliant.
  • Battery-powered for field use.

 

What's in the box?

  • Kusam Meco KM CAL 802 Digital Voltage Tester
  • User Manual
  • Test lead CF-36
  • Clips for probe
  • Holster
  • Carrying case.

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image

Product Specifications

GENERAL

Basic Accuracy : ± 0.05%
Display : 5 Digit LCD display.
Max. Allowable Voltage : 30V.
Operating Temperature Range : 0 ~ 50°C.
Humidity range : = 80% RH
Storage Temperature Range : ≤ -10°C ~ 55°C
Humidity range : ≤ 90% RH
Temperature Coefficient : 0.1 x (dedicated Accuracy) %
  /°C (5°C ~ 18°C, 28°C ~ 40°C)
Power Consumption : about 50m / 3V.
Dimension : 180 (L) x 90 (W) x 47 (D) mm (with protector)
Weight : About 500g.

 

TECHNICAL

OutputRangeOutput RangeResolutionAccuracyRemarks
DC Voltage100mV-10.00 ~ 110.00mV0.01mV±0.05% ± 30μVThe max. Output current ± 2mA
1V-0.1000 ~ 1.1000V0.1mV±0.05% ± 30mV
ThermocoupleR-40 ~ 1760 C1 C±0.05% + 3(Less than or equals to 100 C) O ±0.05% + 2(more than 100 C)Employs ITS-90 temperature standard The accuracy does not include the error of interior temperature compensation sensor The accuracy does not include the impact of interior thermoelectric force.
S-20 ~ 1760 C1 C
RTDB400 ~ 1800 C1 C±0.05% + 3(Less than or equals to 600 C) O ±0.05% + 2(more than 600 C)
E-200.0 ~ 1000.0 C0.1 C±0.05% + 20 (Less than or equals to -100 C) O ±0.05% + 10 (more than -100 C)
K-200.0 ~ 1370 C0.1 C
 J-200.0 ~ 1200.0 C0.1 C
T-200.0 ~ 400.0 C0.1 C
N200.0 ~ 1300.0 C0.1 C
OutputRangeOutput RangeResolutionAccuracyRemarks
DC Voltage100mV-10.00 ~ 110.00mV0.01mV±0.05% ± 3Input Resistance : 1MΩ 

Thermocouple

RTD

R-40 ~ 1760 C1 C±0.05% + 3(Less than or equals to 100 C) O ±0.05% + 2(more than 100 C)

Input Resistance : 1MΩ

Employs ITS-90 temperature standard The accuracy does not include the error of interior temperature compensation sensor The accuracy does not include the impact of interior thermoelectric force

S-200 ~ 1760 C1 C
B400 ~ 1800 C1 C±0.05% + 3(Less than or equals to 600 C) O ±0.05% + 2(more than 600 C)
E-200.0 ~ 1000.0 C0.1 C±0.05% + 20 (Less than or equals to -100 C) ±0.05% + 10 (more than -100 C)
K200.0 ~ 1370 C0.1 C
 J-200.0 ~ 1200.0 C0.1 C
T200.0 ~ 400.0 C0.1 C
N-200.0 ~ 1300.0 C0.1 C

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image