- Home
- About Us
-
Electrical and Electronic
-
Environmental
-
General Laboratory | Analytical
-
Imaging Instruments
-
Mechanical and Quality Control
-
Network and Communication
-
Safety
-
Temperature, Humidity and Pressure
-
Time, Speed and Dimension
-
Tools
-
Calibrators
-
Data Loggers
-
Accessories
-
Shop By Industry
-
Visit Store
- Blogs
- Contact Us
© 2023.INSUZO CORPORATION PRIVATE LIMITED. All Rights Reserved.
Electrical and Electronic
Environmental
General Laboratory | Analytical
Imaging Instruments
Mechanical and Quality Control
Time, Speed and Dimension
Tools
Calibrators
Shop By Industry
Item(s) Added To Your Bag
MECO PHA 5850B Power & Harmonics Analyzer
Click To Zoom
MECO PHA 5850B Power & Harmonics Analyzer
MECO PHA 5850B Power & Harmonics Analyzer
(Based On 10 Reviews)
MECO Power and Harmonics Analyser Model PHA-5850 can Analyze, Measure, Monitor &Data Log values of Power Quality & Consumption (Energy).
Capable of analyzing IT standby power consumption to the maximum demand of factory. It comes with a user friendly application software that increases
the utility & performance of this instrument. The analyzer is ideal for an any Engineer / Inspector for carrying out Periodic Visits, Maintainance of Plant, Vigilance
checks, Surveys and Energy Audits for checking at Industrial and Consumers end.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL PRODUCTS
SECURE PAYMENTS
1 YEAR WARRANTY
AUTHORIZED DISTRIBUTOR
B2B INVOICES
₹ 2,89,188
(GST inclusive price) i-
Base Value: ₹ 245074.6
-
GST: (18) % ₹ 44113.4
-
Total Value ₹ 289188
₹3,74,823.00
( - 23% OFF )
Description
Key Features
- Analysis of 3P4W, 3P3W, 1P2W, 1P3W Systems
- Display of 35 Parameters in one screen (3P4W)
- Programmable CT (1 to 600) and PT (1 to 3000) Ratios
- RMS, PEAK Value & Crest Factor
- True RMS value, Active Power, Apparent & Reactive Power ( KVA, KVAR)
- Power Factor, Phase Angle ( ? ) & Energy (WH, KWH, KVARH, PFH)
- Average / Maximum Demand (KW, MW, KVA, MVA) with Programmable Period
- Display of 50 Harmonics in one Screen with Waveform with Peak value (1024 Sample / Period)
- Analysis of total Harmonics Distortion (THD-F)
- Capture 28 Transient Events with Programmable Threshold (%) (DIP, SWELL & OUTAGE)
- Built-in timer & Calender for Data Logging
- 512K Memory with Programmable interval (2 to 3000 seconds, 17000 records for 3P4W Systems)
- Optical Isolated RS-232C ~ USB Interface
- Calculated Unbalanced Current through Neutral line
- Graphic Phasor Diagram
- Facility to retrieve Power Data & Harmonics on Meter Screen
- Software for easy download of Recorded Data & Transient events
- Graphic Phasor Diagram
- Facility to retrieve Power Data & Harmonics on Meter Screen
- Software for easy download of Recorded Data & Transient events
What's in the box?
|
Rating & Reviews
Rating
| General Specification | |
| Power | Eight x 1.5V AA Batteries |
| External DC Input | Power supply adapter 12 Volts. DC |
| Display | Dot Matrix LCD (240x128) with backlight |
| LCD Update Rate | 1 time / second |
| Power Consumption | 140mA (approx.) |
| No. Of Samples | 1024 samples / period |
| Data Logging Files | 85 |
| Max. File Capacity | 17474 records (3P4W, 3P3W) 26210 records (1P3W) 52420 records (1P2W) 4096 records (50 Harmonics / record) 2 to 3000 seconds for data logging |
| Sampling Time | OL |
| Operating Condition | -10°C to 50°C < 85% RH |
| Storage Condition | -20°C to 60°C < 75% RH |
| Dimensions | 257 x 155 x 57 mm |
| Weight | 1160 g (Batteries included) |
| Model : PHA-5850A (100A) (Overload Protection AC 200A) | ||
| Range | Resolution | Accuracy of Readings |
| 0.04 - 1A | 0.1mA / 1mA | ± 0.5% ± 0.05A |
| 0.4 - 10A | 0.001A / 0.01A | ± 0.5% ± 0.05A |
| 4 - 100A | 0.01A / 0.1A | ± 1.0% ± 0.5A |
| Model : PHA-5850B (1000A) (Overload Protection AC 2000A) | ||
| Range | Resolution | Accuracy of Readings |
| 10.00A | 0.001A / 0.01A | |
| 5A - 100.0A | 0.01A / 0.1A | ± 0.5% ± 0.5A |
| 50A - 1000.0A | 0.1A / 1A | ± 0.5% ± 5A |
| Model : PHA-5850C (3000A) (Overload Protection AC 3000A) | ||
| Range | Resolution | Accuracy of Readings |
| 10.0 - 300.0A | 0.01A / 0.1A | ± 1% of range |
| 300.0 - 3000A | 0.1A / 1A | |
| Model : PHA-5850D (1200A) (Overload Protection AC 1200A) | ||
| Range | Resolution | Accuracy of Readings |
| 6.0 - 120.0A | 0.01A / 0.1A | ± 1% of range |
| 300.0 - 3000A | 0.1A / 1A | |
| Harmonic of AC Voltage in Percentage | ||
| Range | Resolution | Accuracy of Readings |
| 1 - 10th | 0.1% | ± 2% |
| 11 - 20th | ± 4% of reading ± 2.0% | |
| 50 - 99th | ± 6% of reading ± 2.0% | |
| Harmonic of AC Current in Percentage Model : PHA-5850A (100A) | ||
| Range | Resolution | Accuracy of Readings |
| 1 - 10th | 0.1% | ± 0.2% of reading ± 1% |
| 11 - 20th | ± 2% of reading ± 1% | |
| 21 - 50th (A range) | ± 5% of reading ± 1% | |
| 21 - 50th (mA range) | ± 10% of reading ± 1% | |
| 51 - 99th | ± 35% of reading ± 1% | |
| Model : PHA-5850B (1000A) | ||
| Range | Resolution | Accuracy of Readings |
| 1 - 20th | 0.1% | ±2% |
| 21 - 49th | ± 4% of reading ± 2.0% | |
| 50 - 99th | ± 6% of reading ± 2.0% | |
| Model : PHA-5850C (3000A) & PHA-5850D (1200A) | ||
| Range | Resolution | Accuracy of Readings |
| 1 - 20th | 0.1% | ±2 % |
| 21 - 49th | ± 6% | |
| 50 - 99th | ± 10% | |
| Model : PHA-5850A (100A) | ||
| Range | Resolution | Accuracy of Readings |
| 5.0 - 999.9W | 0.1W | ± 1% ± 0.8W |
| 1.000 - 9.999KW | 0.001KW | ± 1% ± 8W |
| 10.00 - 99.99KW | 0.01KW | ± 1% ± 80W |
| 100.0 - 999.9KW | 0.1KW | ± 1% ± 0.8KW |
| 1000 - 9999KW | 1KW | ± 1% ± 8KW |
| Model : PHA-5850B (100A) | ||
| Range | Resolution | Accuracy of Readings |
| 5.0 - 999.9W | 0.1W | ± 1% ± 0.8W |
| 1.000 - 9.999KW | 0.001KW | ± 1% ± 8W |
| 10.00 - 99.99KW | 0.01KW | ± 1% ± 80W |
| 100.0 - 999.9KW | 0.1KW | ± 1% ± 0.8KW |
| 1000 - 9999KW | 1KW | ± 1% ± 8KW |
| 0.000 - 9.999MW | 0.001MW | ± 1% ± 80KW |
| Model : PHA-5850C (3000A) Model : PHA-5850D (1200A) | |||
| Range | Resolution | Accuracy of Readings | |
| 10.0 - 999.9W | 0.1W | >20V & >30A | <20V or <30A |
| 1.000 - 9.999KW | 0.001KW | ± 1% of range | ± 2% of range |
| 10.00 - 99.99KW | 0.01KW | ||
| 100.0 - 999.9KW | 0.1KW | ||
| 1000 - 9999KW | 1KW | ||
| AC Voltage (50Hz or 60H | ||
| Range | Resolution | Accuracy of Readings |
| 20.0V - 500.0V (Phase to Neutral) | 0.1V | ± 0.5% ± 5dgts |
| Power Factor (PF) Model : PHA-5850A (100A) & PHA-5850B (1000A) | ||
| Range | Resolution | Accuracy of Readings |
| 0.00 - 1.00 | 0.1V | ± 0.04 |
| Model : PHA-5850C (3000A) & PHA-5850D (1200A) | |||
| Range | Resolution | Accuracy of Readings | |
| 0.000 - 1.000 | 0.001 | >20V & >30A | <20V or <30A |
| ± 0.04 | ± 0.1 | ||
Rating & Reviews
Rating
Similar Products
Request Callback
We will get in touch with you
Brand Products
MECO
MECO PM-VAC-5R DIGITAL MULTI-RANGE PORTABLE METER
₹ 3,078
₹ 3,996
Add To Cart
MECO
MECO PM-VDC-5R DIGITAL MULTI-RANGE PORTABLE METER
₹ 2,978
₹ 3,861
Add To Cart
MECO
MECO PM-AAC-5R DIGITAL MULTI-RANGE PORTABLE METER
₹ 3,276
₹ 4,248
Add To Cart
MECO
MECO PM-ADC-5R DIGITAL MULTI-RANGE PORTABLE METER
₹ 3,177
₹ 4,122
Add To Cart
Enter your requirement details!
We will get in touch with you.
Reach Us
-
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034
-
For Support
8920884830
-
Send Us Email
info@insuzo.com
Copyright © 2024. INSUZO CORPORATION PRIVATE LIMITED
All Rights Reserved.