Metravi DT-9250 Digital TRMS AC|DC Clamp Meter
Metravi DT-9250 Digital TRMS AC|DC Clamp Meter
(Based On 10 Reviews)
The Metravi DT-9250 is a Digital AC TRMS/DC clamp meters with big jaw dia which can be used anywhere that high current and voltage measurements are needed. The unique feature of the DT-9250 is that it can measure Frequency through the Clamp Jaw, so it can measure the frequency at high current as well. It becomes very safe to take frequency measurements as you do not need to touch high current lines with probes to get frequency measurements.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 9,400.00
(GST inclusive price) i₹12,690.00
( - 26% OFF )
Description
What's in the box?
|
Rating & Reviews
Rating
General Specification | |
Clamp Jaw Opening | 2” (52mm) approx |
Display | 3-3/4 digits (4000 counts) Backlit LCD |
Continuity Check | Buzzer sound at less than (60±30)W |
Diode Test | Test current of 0.5mA typical; Open circuit voltage <2VDC typical |
Low Battery Indication | low battery symbol is displayed |
Over-Range Indication | ‘OL’ display |
Measurement Rate | 2 readings per second, nominal |
PEAK | Captures peaks > 1ms |
Temperature Sensor | Type K thermocouple |
Input Impedance | 10MW (VDC and VAC) |
Operating Temperature | 41°F to 104°F (5°C to 40°C) |
Storage Temperature | -4°F to 104°F (-20°C to 60°C) |
Operating Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C) |
Storage Humidity | <80% |
Operating Altitude | 7000ft. (2000meters) maximum |
Battery | One (1) 9V Battery |
Auto Range | Auto/Manual |
Auto Power OFF | After approx. 15 minutes |
Dimensions & Weigh | 27cm (H) x 10cm (W) x 4cm (D), 600 Grams Approx. |
Safety | For indoor use and in accordance with the requirements for double insulation to IEC 1010-1 (2001) : EN61010-1 (2001) Over Voltage Category III 1000V and Category IV 600V, Pollution Degree |
Technical Specification | ||
DC Voltage | ||
Range | Accuracy (% of reading + digits) | Resolution |
400mV | ± (1% + 10 digit) | 0.1mV |
4V | ± (1% + 3 digt) | 1mV |
40V | 10mV | |
400V | 100mV | |
1000V | 1V |
AC Voltage | ||
Range | Accuracy (% of reading + digits) | Resolution |
4V | ± (1.2% + 5 digit) | 1mV |
40V | 10mV | |
400V | 100mV | |
1000V | 1V |
AC Current | ||
Range | Accuracy (% of reading + digits) | Resolution |
400A | ± (3.0% +2A) | 100mA |
2000A | ± (3.5% + 5 digit) | 1A |
DC Current | ||
Range | Accuracy (% of reading + digits) | Resolution |
400A | ± (3.0% + 1A) | 100mA |
2000A | ± (3.5% + 5 digt) | 1A |
Resistance | ||
Range | Accuracy (% of reading + digits) | Resolution |
400Ω | ± (1.0% + 4 digit) | 0.1Ω |
4kΩ | ± (1.5% + 4 digit) | 1Ω |
40kΩ | 10Ω | |
400kΩ | 100Ω | |
4MΩ | 1kΩ | |
40MΩ | ± (2.0% + 4 digit) | 10kΩ |
Frequency (Auto-Ranging) | |
Range | Accuracy (% of reading + digits) |
10Hz to 100kHz | ± 1.0% ±5 digt |
Duty Cycle | ||
Range | Accuracy (% of reading + digits) | Resolution |
(0.1% to 99.9%) | ± (1.2% + 5 digit) | 0.1% |
Temperature | ||
Range | Accuracy (% of reading + digits) | Resolution |
(-20 to 1000°C) | ± (2.0% + 5°C) | 0.1°C |
(-4 to 1832°F) | ± (3.0% + 9°C) | 0.1°F |
Continuity | |
Testing Condition | Reading |
Open voltage is approx. 0.5V | Buzzer makes a long sound, While resistance is less than (60±30W) |
Peak of AC Current | ||
Range | Accuracy (% of reading + digits) | Resolution |
400A | ± (4.0% + 5 digit) | 100mA |
2000A | ± (4.0% + 5 digit) | 1A |
Capacitance | ||
Range | Accuracy (% of reading + digits) | Resolution |
4nF | ± (5.0% + 30 digt) | 0.1nF |
40nF | ± (5.0% + 20 digt) | 1nF |
400nF | ± (3.5% + 10 digt) | 10nF |
4µF | ± (5.0% + 10 digt) | 100nF |
40µF | 1µF | |
400µF | 10µF |
Diode | |
Testing Condition | Reading |
Forward DCA is approx. 0.5mA, backward Voltage is approx. 2V | Forward voltage drop of Diode |
Rating & Reviews
Rating
Similar Products
Request Callback
We will get in touch with you
Enter your requirement details!
We will get in touch with you.
Share This Product
Reach Us
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034
For Support
8920884830
Send Us Email
info@insuzo.com
Copyright © 2024. Insuzo
All Rights Reserved.