Metravi METRACLAMP-15 Digital TRMS AC|DC Clamp Meter
Metravi METRACLAMP-15 Digital TRMS AC|DC Clamp Meter
(Based On 10 Reviews)
3-3/4 Digits, 3999 Counts backlit Display, Measures 1000A AC T-RMS / DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency and Temperature. With Data Hold and Auto Power Off, Non Contact Voltage Detector.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 8,600.00
(GST inclusive price) i₹11,610.00
( - 26% OFF )
Description
What's in the box?
|
Rating & Reviews
Rating
General Specification | |
Clamp jaw opening | 2" (52mm) approx. |
Display | 3-3/4 digits (4000 counts) backlit LCD |
Continuity check | Threshold 400; Test current < 0.5mA |
Diode test | Test current of 0.3mA typical; Open circuit voltage < 3VDC typical |
Low Battery indication | Low Batter symbol is displayed |
Over-range indication | 'OL' display |
Measurement rate | 2 readings per second, nominal |
PEAK HOLD | Captures peaks >1ms |
DATA HOLD | To freeze the displayed data |
Temperature sensor | Type K thermocouple |
Input Impedance | 10ΜΩ (VDC and VAC) |
AC response | True rms (AAC and VAC) |
Operating Temperature | 41°F to 104°F (5°C to 40°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Operating Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C) |
Battery | One (1) 9V Battery |
Auto power OFF | After approx. 30 minutes |
Dimensions & Weight | 270 x 100 x 47mm; 449g |
Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 1000V and Category IV 600V, Pollution Degree 2. |
Auto Power Off | Switches meter off when not in use |
Non Contact Voltage Detector | Indicates whether the line is live or dead. |
Relative | Helps perform relative measurements |
Technical Specification | ||
Function | Range & Resolution | Accuracy (% of reading) |
AC Current 50/60 HzTrue RMS | 40.00A AC | ± (2.8% + 10d) |
400.0A AC | ±(2.8% + 8d) | |
1000.0A AC | ± (3% + 8d) | |
DC Current | 40.00A DC | ± (2.8% + 10d) |
400.0A DC | ±(2.8% + 8d) | |
1000A DC | ± (3% + 8d) | |
AC Voltage50/60HzTrue RMS | 400.0mV AC | ± (1% + 10d) |
4.000V AC | ± (1.5% + 5d) | |
40.00V AC | ||
400.0V AC | ||
600V AC | ± (2% + 8d) | |
DC Voltage | 400.0mV DC | ± (0.8% + 2d) |
4.000V DC | ± (1.5% + 2d)
| |
40.00V DC | ||
400.0V DC | ||
600V DC | ± (2% + 2d) | |
Resistance | 400.0Ω | ± (1% + 4d) |
4.000ΚΩ | ± (1.5% + 2d) | |
40.00ΚΩ | ||
400.0ΚΩ | ||
4.000ΜΩ | ± (2.5% + 5d) | |
40.00ΜΩ | ± (3.5% + 10d) | |
Capacitance | 4.000nF | ± (5% + 30d) |
40.00nF | ± (5% + 20d) | |
400.0nF | ± (3% + 5d) | |
4.000μF | ||
40.00μF | ||
400.0μF | ||
4.000mF | ± (4% + 10d) | |
40.00mF | ± (4.5% + 10d) | |
Frequency | 4.000kHz | ± (1.5% +20) |
Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401 to 4000Hz) | ||
Temperature | -4 to 1400°F | ± (3%rdg +9°F) |
-20 to 760°C | ± (3%rdg +5°C) |
Rating & Reviews
Rating
Similar Products
Request Callback
We will get in touch with you
Enter your requirement details!
We will get in touch with you.
Share This Product
Reach Us
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034
For Support
8920884830
Send Us Email
info@insuzo.com
Copyright © 2024. Insuzo
All Rights Reserved.