Item(s) Added To Your Bag

METRAVI CAL-ER Earth and Ground Tester Calibrator

Click To Zoom

METRAVI CAL-ER Earth and Ground Tester Calibrator

METRAVI CAL-ER Earth and Ground Tester Calibrator

(Based On 10 Reviews)

The Metravi CAL-ER Earth and Ground Tester Calibrator is used for calibrating grounding resistance testers, equipotential testers and other instruments which require a standard resistor.It is widely used in building quality inspection stations, supervision companies, construction companies, lightning protection companies, electric power departments, etc. 

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL PRODUCTS
Your source for authentic goods. No fakes, just the real deal.

100% ORIGINAL PRODUCTS

SECURE PAYMENTS
Risk-free Transactions

SECURE PAYMENTS

1 YEAR WARRANTY
1 Year Warranty Against Any Manufacturing Defects.

1 YEAR WARRANTY

AUTHORIZED DISTRIBUTOR
Get genuine products and full manufacturer support. We are an authorized distributor for Fluke, Metravi, Mextech, Lutron & SEW.

AUTHORIZED DISTRIBUTOR

B2B INVOICES
Enter your GSTIN at the time of checkout for claiming GST input.

B2B INVOICES

₹ 34,509.00

(GST inclusive price) i
  • Base Value: ₹ 29244.9
  • GST: (18) % ₹ 5264.1
  • Total Value ₹ 34509

₹46,500.00

( - 26% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • The military grade instrument is composed of 9 pieces of 1/2w, high-precision, military-grade wire wound resistors.
  • It has stable performance and strong structure, especially convenient for calibration & testing.
  • When calibrating resistors, one can direct shift and test without replacing the test line.
  • Fully meets the national weather service order "lightning protection device detection qualification management approach" specified in the range of 10-3 ~ 105 Ω.

 

What's in the box?

  • METRAVI CAL-ER Earth and Ground Tester Calibrator

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image

Product Specifications

FunctionUsed for calibration of grounding resistance tester, equipotential tester and other instrument
Range and Accuracy0.001Ω; 2%
0.01Ω; 0.5%
0.1Ω; 0.2%
1.0Ω; 0.2%
10Ω; 0.05%
100Ω; 0.05%
1KΩ; 0.05%
10KΩ; 0.05%
100KΩ; 0.05%
Connection Wire Method 4-wire method
Power1/2W
Temperature Coefficient±25ppm
Dimensions173mmX125mmX70mm
Weight350g
Test LineRed 0.5m & black 0.5m, each with 2pcs
Working Temperature and Humidity-10℃~40℃;80%rh below
Storage Temperature and Humidity-20℃~60℃;70%rh below
Insulation Resistance10MΩ above(between the circuit and shell 500V)
Withstand VoltageAC 3700V/rms(between the circuit and shell)
Suitable Safety StandardIEC61010-1,CAT Ⅲ 600V,Polluted Gradation