Item(s) Added To Your Bag
METRAVI Metrasafe-18 Digital Multimeter
METRAVI Metrasafe-18 Digital Multimeter
The Metravi Metrasafe‑18 is a robust 4¾‑digit digital TRMS multimeter with backlit LCD and analogue bargraph display. Featuring full protection, IP‑67 sealing, CAT IV 600 V safety, data/peak hold, max/min recording and broad electrical measurement capabilities
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL PRODUCTS
SECURE PAYMENTS
1 YEAR WARRANTY
AUTHORIZED DISTRIBUTOR
B2B INVOICES
₹ 15,309.00
(GST inclusive price) i₹20,608.00
( - 26% OFF )
Description
What's in the box?
|
Enclosure Double molded, waterproof
Shock (Drop Test) 6.5 feet (2 meters)
PEAK Captures peaks >1ms
Input Impedance >10MΩ VDC & >3MΩ VAC
AC Response True rms
AC True RMS The term stands for "Root-Mean-Square," which represents the method of calculation of the voltage or current value. Average responding multimeters are calibrated to read correctly only on sine waves and they will read inaccurately on non-sine wave or distorted signals. True rms meters read accurately on either type of signal.
ACV Bandwidth 50Hz to 1000Hz
Crest Factor <3 at full scale up to 500V, decreasing linearly to <1.5 at 1000V
Display 4-3/4 Digits 40,000 count backlit liquid crystal with 41 segment analogue bargraph
Overrange indication "OL" is displayed
Auto Power Off 15 minutes (approximately) with disable feature Polarity Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate 2 times per second, nominal
Low Battery Indication " " is displayed if battery voltage drops below operating voltage
Battery One 9 volt (NEDA 1604) battery
Fuses mA, µA ranges; 0.5A/1000V ceramic fast blow A range; 10A/1000V ceramic fast blow
Operating Temperature 41ºF to 104ºF (5ºC to 40ºC)
Storage Temperature -4oF to 140oF (-20oC to 60oC)
Operating Humidity Max 80% up to 87ºF (31ºC) decreasing linearly
to 50% at 104ºF (40ºC)
Storage Humidity <80%
Operating Altitude 7000ft. (2000meters) maximum.
Weight 0.753lb (342g) (includes holster).
Size 7.36" x 3.2" x 2.0" (187 x 81 x 50mm) (includes holster)
Data Hold To freeze the display data
Max/Min To record Max/Min Data
Peak Hold To freeze the peak values
Relative measurement facility
Function | Range | Resolution | Accuracy |
DC Voltage | 400mV | 0.01mV |
±(0.06% reading + 2 digits) |
4V | 0.0001V | ||
40V | 0.001V | ||
400V | 0.01V | ||
1000V | 0.1V | ±(0.1% reading + 5 digits) | |
AC Voltage |
| 50 to 1000Hz | |
400mV | 0.1mV | ±(1.0% reading + 5 digits) | |
4V | 0.001V |
±(1.0% reading + 3 digits) | |
40V | 0.01V | ||
400V | 0.1V | ||
1000V | 1V | ||
All AC voltage rangesare specified from5% of rangeto 100% of range | |||
DC Current | 400μA | 0.01μA |
±(1.0% reading + 3 digits) |
4000μA | 0.1μA | ||
40mA | 0.001mA | ||
400mA | 0.01mA | ||
10A | 0.001A | ||
(20A: 30 sec max with reduced accuracy) | |||
AC Current |
| 50 to 1000Hz | |
400μA | 0.1μA |
±(1.5% reading + 3 digits) | |
4000μA | 1μA | ||
40mA | 0.01mA | ||
400mA | 0.1mA | ||
10A | 0.01A | ||
(20A: 30 sec max with reduced accuracy) | |||
All AC voltage rangesare specified from5% of rangeto 100% of range | |||
Diode Test
Continuity | Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical Audible signal will sound if the resistance is less than 35Ω | ||
Check Temperature | (approx.), test current <0.35mA Requires type K thermocouple for measurement of | ||
Sensor | temperature as a contact type thermometer and requires infra red temperature adaptor TS-03 to measure temperature as a non contact type infra red thermometer. | ||
Resistance | 400Ω | 0.01Ω | ±(0.3% reading + 9 digits) |
4kΩ | 0.0001kΩ |
±(0.3% reading + 4 digits) | |
40kΩ | 0.001kΩ | ||
400kΩ | 0.01kΩ | ||
4MΩ | 0.001MΩ | ||
40MΩ | 0.001MΩ | ±(2.0% reading + 10 digits) | |
Capacitance | 40n | 0.001nF | ±(3.5% reading + 40 digits) |
400n | 0.01n | ||
4µ | 0.0001µ |
±(3.5% reading + 10 digits) | |
40µ | 0.001µF | ||
400µ | 0.01µ | ||
4000µ | 0.1µF | ±(5% reading + 10 digits) | |
40m | 0.001m | ||
Frequency (electronic) | 40Hz | 0.001Hz |
±(0.1% reading + 1 digits) |
400Hz | 0.01Hz | ||
4kHz | 0.0001kHz | ||
40kHz | 0.001kHz | ||
400kHz | 0.01kHz | ||
4MHz | 0.0001MHz | ||
40MHz | 0.001MHz | ||
100MHz | 0.01MHz | Not specified | |
Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle & <100kHz; 5Vrms min @ 20% to 80% duty cycle & > 100kHz. | |||
Frequency (electrical) | 40.00-400Hz | 0.01Hz | ±(0.5% reading) |
Sensitivity: 15Vrms | |||
Duty Cycle | 0.1 to 99.90% | 0.01% | ±(1.2% reading + 2 digits) |
Pulse width: 100µs- 100ms, Frequency: 5Hz to 150kHz | |||
Temp (type-K) | -58 to 1832° | 1°F | ±(1.0% reading + 4.5°F) ±(1.0% reading + 2.5°C) (probe accuracy not included) |
-20 to 1000°C | 1°C | ||
4-20mA% | -25 to 125% | 0.01% | ±50 digits |
Similar Products
Request Callback
We will get in touch with you
More From Brands
Enter your requirement details!
We will get in touch with you.