Item(s) Added To Your Bag
Metravi PRO 21 Industrial Grade Digital TRMS Multimeter with 700V VFD
Metravi PRO 21 Industrial Grade Digital TRMS Multimeter with 700V VFD
The Metravi PRO‑21 is a heavy‑duty industrial True RMS multimeter featuring VFD measurement, a large backlit 6000‑count LCD display, auto‑ranging, and IP67 dust/water protection. It’s drop‑proof up to 2m and built for demanding field‑work.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL PRODUCTS
SECURE PAYMENTS
1 YEAR WARRANTY
AUTHORIZED DISTRIBUTOR
B2B INVOICES
₹ 5,939.00
(GST inclusive price) i₹7,992.00
( - 26% OFF )
Description
What's in the box?
|
Product Specifications
Enclosure : DoubleMoulded,Waterproof
Shock(DropTest): 6.5feet(2 meters)
Diode Test: Testcurrentof 0.9mAmaximum open circuit voltage approx 3.2V DC typical.
ContinuityCheck: Audible signal will sound if the resistance is Less than 50W (approx.), test current <0.35mA.
Input Impedance : > 10MWVDC & > 10MW VAC.
AC Response: True RMS.
ACV Bandwidth: 45Hz to 1KHz.
CrestFactor : ≤ 3 at full scale up to 500V, decreasing linearly to ≤ 1.5 at 1000V.
Display: 6,000 Counts backlit liquid crystal with bargraph.
Overrange indication : “OL” is displayed.
Text Box: *Technical Specifications & Appearance are subject to change wi hout prior noticeAuto Power Off : 15 minutes(Approximately) with disablefeature. Polarity : Automatic(No indication for positive); Minus (-) sign for negative. Measurement Rate : 2 times per second, nominal.
Peak:Captures peaks> 1 ms.
Low Battery Indication : “ “ is displayedif battery voltage drops below operating voltage.
Battery: One 9 Volt (NEDA 1604) battery.
Fuses: mA, μA ranges; 0.8A/1000V ceramic fast blow A range; 10A/1000V ceramic fast blow.
Operating Temperature : 5 to 40°C (41 to 104°F)
Storage Temperature : -20 to 60°C (-4 to 140°F)
Operating Humidity : Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity : <80%
OperatingAltitude: 2000 meters (7000 ft) maximum.
Safety: This meter is intended for origin of installation use and protected, against the users, by double insulation per EN61010-1 and IEC61010 1, 2nd Edition (2001)to CategoryIV 600Vand CategoryIII 1000V;Pollution Degree2. Themeter alsomeets UL 61010-1, 2nd Edition (2004).CAN/CSA C22.2 No. 61010 -1, 2nd Edition (2004).and UL 610108-2-031, 1st Edition (2003).
DC Voltage
Range | Resolution | Accuracy |
60.00mV | 0.01mV | ±(0.9% + 9 digits) |
600.0mV | 0.1mV | |
6.000V | 0.001V | ±(0.5% + 5 digits) |
60.00V | 0.01V | |
600.0V | 0.1V | ±(0.6% + 6 digits) |
1000V | 1V |
AC Voltage(45Hz to 1KHz) T-RMS
Range | Resolution | Accuracy |
60.00mV | 0.01mV | ±(0.9% + 9 digits) |
600.0mV | 0.1mV |
±(0.8% + 3 digits) |
6.000V | 0.001V | |
60.00V | 0.01V | |
600.0V | 0.1V | |
1000V | 1V | ±(0.8% + 8 digits) |
AllAC voltage rangesare specifie from5% of range to 100% of range. AC voltage bandwidth: 45Hz to1kHz(Sine); 45Hz to 60Hz (All wave). |
VFD
Range | Resolution | Accuracy |
50.0 to 700V | 0.1V/1V | ±(4% + 3 digits) |
DC Current
Range | Resolution | Accuracy |
600.0μA | 0.1μA |
±(1 .0%+ 3 digits) |
6000μA | 1μA | |
60.00mA | 0.01mA | |
600.0mA | 0.1mA | |
6.000A | 0.01A | ±(1.5% + 3 digits) |
10.00A | 0.01A |
(10A: 30 sec max with reduced accuracy)
Capacitance
Range | Resolution | Accuracy |
99.99nF* | 0.01nF | ±(5.0% + 20 digits) |
999.9nF | 0.1nF |
±(4.0% + 5 digits) |
9.999μF | 0.001μF | |
99.99μF | 0.01μF | |
999.9μF | 0.1μF | |
9.999mF | 0.001mF | ± 10%reading |
99.99mF | 0.01mF |
AC Current(45Hz to 1 KHz) T-RMS
Range | Resolution | Accuracy |
600.0μA | 0.1μA |
±(1.5% + 3 digits) |
6000μA | 1μA | |
60.00mA | 0.01mA | |
600.0mA | 0.1mA | |
6.000A | 0.001A | ±(2.0% + 3 digits) |
10.00A | 0.01A | |
(10A: 30 sec max with reduced accuracy) AllAC voltage rangesare specifie from5% of range to 100% of range. ACvoltagebandwidth:45Hz to 1kHz(Sine); 50/60Hz (All wave). |
Resistance
Range | Resolution | Accuracy |
600.0W | 0.1W | ±(1.0% + 2 digits) |
6.000kW | 0.001kW |
±(0.8% + 2 digits) |
60.00kW | 0.01kW | |
600.0kW | 0.1kW | |
6.000MW | 0.001MW | ±(1.2% + 2 digits) |
60.00MW | 0.01MW | ±(1.0% + 5 digits) |
Frequency (Electronic)
Range | Resolution | Accuracy |
9.999Hz | 0.001Hz |
±(0.1 % + 4 digits) |
99.99Hz | 0.01Hz | |
999.9Hz | 0.1Hz | |
9.999kHz | 0.001kHz | |
99.99kHz | 0.01kHz | |
999. 9kHz | 0.1kHz | |
9.999MHz | 0.001MHz | |
Sensitivity:0.8V RMS min. at 20% to 80% duty cycle and <100kHz; 5Vrms min at 20% to 80% duty cycle and >100kHz |
Frequency (Electrical)
Range | Resolution | Accuracy |
10.00 - 1kHz | 0.01Hz | ±0.5% reading |
Sensitivity: ACmV Range (≥100mV), ACV Range (≥6% Range) 6000μA/600.0mA/10.00A Range (≥6%Range); 600.0μA/60.00mA/6.000A (≥60% Range). |
Duty Cycle
Range | Resolution | Accuracy |
0.1 to 99.9% | 0.1% | ±(1.2% + 2 digits) |
Pulse width:100μs-100ms; Frequency: 5Hz to 150kHz.
|
Temperature (Type-K)
Range | Resolution | Accuracy |
-40 to 1000°C | 1°C | ±(3.0% + 3°C/5°Fdigits) (Probe accuracy not included) |
-40 to 1832°F | 1°F |
Similar Products