Item(s) Added To Your Bag

Metravi Metrasafe-13 Digital Multimeter - fully-protected & IP67 waterproof

Click To Zoom

Metravi Metrasafe-13 Digital Multimeter - fully-protected & IP67 waterproof

Metravi Metrasafe-13 Digital Multimeter - fully-protected & IP67 waterproof

(Based On 10 Reviews)

The Metravi Metrasafe‑13 is a rugged, fully protected digital multimeter (3¾ digits, 4000 counts) with autoranging, backlit display, IP67 dust/water protection, and comprehensive measurement capabilities (voltage, current, resistance, capacitance, frequency, continuity) — certified to CAT IV 600V.

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL PRODUCTS
Your source for authentic goods. No fakes, just the real deal.

100% ORIGINAL PRODUCTS

SECURE PAYMENTS
Risk-free Transactions

SECURE PAYMENTS

AUTHORIZED DISTRIBUTOR
Get genuine products and full manufacturer support. We are an authorized distributor for Fluke, Metravi, Mextech, Lutron & SEW.

AUTHORIZED DISTRIBUTOR

B2B INVOICES
Enter your GSTIN at the time of checkout for claiming GST input.

B2B INVOICES

₹ 4,769.00

(GST inclusive price) i
  • Base Value: ₹ 4041.5
  • GST: (18) % ₹ 727.5
  • Total Value ₹ 4769

₹6,413.00

( - 26% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Overload protection up to 1200V DC / AC RMS in the AC/DC Voltage range.
  • Overload protection up to 20A DC/AC RMS by fast blow fuse in the AC/DC Current range.
  • Overload protection up to 600V DC / AC RMS in the capacitance, Frequency, Temperature, Resistance, Continuity and Diode Test Range.
  • The instrument has overload protection up to 20A DC/AC RMS in the Voltage Range and 1000V DC/AC RMS in the Current Range.
  • Surge Protection of 8 kV peak IEC 61010
  • O Ring Seal body.
  • The instrument has IP-67 Protection making the body water proof even if dipped in 1m. deep water for 30 mins.
  • Double molded injection body with rubber lining to provide insulation against electrical shocks and anti-slip grip.
  • Confirms to EN61010-1, CAT IV 600V, CAT III 1000V.
  • Two year warrantyagainst manufacturing defects

 

What's in the box?

  • Metravi Metrasafe-13 Digital Multimeter

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image

Product Specifications

GENERAL

The instrument complies with : IEC61010-1:2001 and IEC, 61010-031:2002
Insulation : Class2, Double insulation.
Overvoltage category  : CATIII 1000V, CAT IV 600V.
Display    : 4000 counts Backlit LCD display with function indicator
Polarity    : Automatic, (-) negative polarity indication.
Overrange    : "OL" mark indication.
Low battery indication    : The "BAT" is displayed when the battery voltage drops below the operating level.
Measurement rate    : 2 times per second, nominal.
Auto power off    : Meter automatically shuts down after approx. 15 minutes of inactivity.
Operating environment    : 0ºC to 50ºC (32ºF to 122ºF) @ 70% R.H. Storage temperature    : -20ºC to 60ºC (-4ºF to 140ºF) @ < 80% R.H. For inside use, max height    : 2000m
Pollution degree    : 2
Power    : One 9V battery , NEDA 1604, IEC 6F22.
Dimensions    : 182 (H) x 82 (W) x55 (D) mm
Weight    : Approx.: 375g.
Data Hold    : Freezes the displayed data Relative measurement facility

 

TECHNICAL

DC Voltage (Auto-ranging)

Range

Resolution

Accuracy

400.0mV

0.1mV

± 0.5% of rdg + 2 dgts

4.000V

1mV

 

± 1.2% of rdg + 2 dgts

40.00V

10mV

400.0V

100mV

1000V

1V

± 1.5% of rdg + 2 dgts

Input Impedance        : 7.8MΩ.

Maximum Input         :  1200V DC or 1200V AC rms

AC Voltage (Auto-ranging except 400mV)

Range

Resolution

Accuracy

400.0mV

0.1mV

± 1.5% of rdg ± 30 dgts

4.000V

1mV

± 1.2% of rdg ± 3 dgts

40.00V

10mV

± 1.5% of rdg ± 3 dgts

400.0V

100mV

1000V

1V

± 2.0% of rdg + 4 dgts

Input Impedance        : 7.8MΩ.

AC Response           : 50 Hz to 400 Hz

Maximum Input         :  1200V DC or 1200V AC rms.

DC Current (Auto-rangingfor uA and mA)

Range

Resolution

Accuracy

400.0uA

0.1uA

± 1.0% of rdg + 3 dgts

4000uA

1uA

 

± 1.5% of rdg ± 3 dgts

40.00mA

10uA

400.0mA

100uA

20A

10mA

± 2.5% of rdg + 5 dgts

Overload Protection  :  0.5A / 1000V and 20A / 500V Fuse

Maximum Input         : 400mA DC or 400mA AC rms on

uA / ma ranges, 20A DC or AC rms on 20A range

Note: 10A continuous, 20A for 30 seconds max with a 15 minute cool down interval

AC Current (Auto-ranging for uA and mA)

Range

Resolution

Accuracy

400.0uA

0.1uA

± 1.5% of rdg + 5 dgts

4000uA

1uA

 

± 1.8% of rdg + 5 dgts

40.00mA

10uA

400.0mA

100uA

20A

10mA

± 3.0% of rdg + 7 dgts

Overload Protection  :  0.5A / 1000V and 10A / 500V Fuse

AC Response           : 50 Hz to 400 Hz

Maximum Input         : 400mA DC or 400mA AC rms on uA

/ ma ranges, 20A DC or AC rms on 20A range

Note: 10A continuous, 20A for 30 seconds max with a 15 minute cool down interval

Resistance (Auto-ranging)

Range

Resolution

Accuracy

400.0Ω

0.1Ω

± 1.2% of rdg ± 4 dgts

4000kΩ

± 1.0% of rdg ± 2 dgts

40.00kΩ

10Ω

 

± 1.2% of rdg ± 2 dgts

400.0kΩ

100Ω

4.00MΩ

1kΩ

40.00MΩ

10kΩ

± 2.0% of rdg ± 7 dgts

Input Protection        : 600V DC or 600V AC rms

Capacitance (Auto-ranging)

Range

Resolution

Accuracy

4.000nF

1pF

± 5.0% of rdg ± 0.2 nF

40.00nF

10 pF

± 5.0% of rdg ± 7 dgts

400.0nF

0.1nF

 

± 3.0% of rdg ± 5 dgts

4.000uF

1nF

40.00uF

10nF

200.0uF

0.1uF

± 5.0% of rdg ± 5 dgts

Input Protection        : 600V DC or 600V AC rms

Frequency (Auto-ranging)

Range

Resolution

Accuracy

9.999Hz

0.001 Hz

 

± 1.5% of rdg ± 5 dgts

99.99Hz

0.01 Hz

999.9Hz

0.1 Hz

 

 

± 1.2% of rdg ± 3 dgts

9.999kHz

1Hz

99.99kHz

10Hz

999.9kHz

100Hz

9.999MHz

1kHz

± 1.5% of rdg ± 4 dgts

Sensitivity               : > 0.5V RMS while ≤ 1MHz

Sensitivity               : > 3V RMS while > 1MHz

Overload protection : 600V DC or AC rms

Duty Cycle

Range

Resolution

Accuracy

0.1%~99.9%

0.1%

± 1.2% of rdg ± 2 dgts

Pulse width              : > 100us, < 100ms 

Frequency width     : 5Hz - 150kHz 

Sensitivity     : > 0.5V RMS 

Overload protection :600V DC or AC rms

Diode Text

Test Current

Resolution

Accuracy

0.3mA

typical

1 mV

± 10% of rdg ± 5 dgts

Open circuit voltage : 1.5V DC typical

Overload protection : 600V DC or AC rms

Audible continuity

Audible threshold      : Less than 150Ω

Test current               : < 0.3 mA

Overload protection : 600V DC or AC rms

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image