Item(s) Added To Your Bag
Metravi Metrasafe-13 Digital Multimeter - fully-protected & IP67 waterproof
Metravi Metrasafe-13 Digital Multimeter - fully-protected & IP67 waterproof
The Metravi Metrasafe‑13 is a rugged, fully protected digital multimeter (3¾ digits, 4000 counts) with autoranging, backlit display, IP67 dust/water protection, and comprehensive measurement capabilities (voltage, current, resistance, capacitance, frequency, continuity) — certified to CAT IV 600V.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL PRODUCTS
SECURE PAYMENTS
AUTHORIZED DISTRIBUTOR
B2B INVOICES
₹ 4,769.00
(GST inclusive price) i₹6,413.00
( - 26% OFF )
Description
What's in the box?
|
The instrument complies with : IEC61010-1:2001 and IEC, 61010-031:2002
Insulation : Class2, Double insulation.
Overvoltage category : CATIII 1000V, CAT IV 600V.
Display : 4000 counts Backlit LCD display with function indicator
Polarity : Automatic, (-) negative polarity indication.
Overrange : "OL" mark indication.
Low battery indication : The "BAT" is displayed when the battery voltage drops below the operating level.
Measurement rate : 2 times per second, nominal.
Auto power off : Meter automatically shuts down after approx. 15 minutes of inactivity.
Operating environment : 0ºC to 50ºC (32ºF to 122ºF) @ 70% R.H. Storage temperature : -20ºC to 60ºC (-4ºF to 140ºF) @ < 80% R.H. For inside use, max height : 2000m
Pollution degree : 2
Power : One 9V battery , NEDA 1604, IEC 6F22.
Dimensions : 182 (H) x 82 (W) x55 (D) mm
Weight : Approx.: 375g.
Data Hold : Freezes the displayed data Relative measurement facility
DC Voltage (Auto-ranging)
Range | Resolution | Accuracy |
400.0mV | 0.1mV | ± 0.5% of rdg + 2 dgts |
4.000V | 1mV |
± 1.2% of rdg + 2 dgts |
40.00V | 10mV | |
400.0V | 100mV | |
1000V | 1V | ± 1.5% of rdg + 2 dgts |
Input Impedance : 7.8MΩ.
Maximum Input : 1200V DC or 1200V AC rms
AC Voltage (Auto-ranging except 400mV)
Range | Resolution | Accuracy |
400.0mV | 0.1mV | ± 1.5% of rdg ± 30 dgts |
4.000V | 1mV | ± 1.2% of rdg ± 3 dgts |
40.00V | 10mV | ± 1.5% of rdg ± 3 dgts |
400.0V | 100mV | |
1000V | 1V | ± 2.0% of rdg + 4 dgts |
Input Impedance : 7.8MΩ.
AC Response : 50 Hz to 400 Hz
Maximum Input : 1200V DC or 1200V AC rms.
DC Current (Auto-rangingfor uA and mA)
Range | Resolution | Accuracy |
400.0uA | 0.1uA | ± 1.0% of rdg + 3 dgts |
4000uA | 1uA |
± 1.5% of rdg ± 3 dgts |
40.00mA | 10uA | |
400.0mA | 100uA | |
20A | 10mA | ± 2.5% of rdg + 5 dgts |
Overload Protection : 0.5A / 1000V and 20A / 500V Fuse
Maximum Input : 400mA DC or 400mA AC rms on
uA / ma ranges, 20A DC or AC rms on 20A range
Note: 10A continuous, 20A for 30 seconds max with a 15 minute cool down interval
AC Current (Auto-ranging for uA and mA)
Range | Resolution | Accuracy |
400.0uA | 0.1uA | ± 1.5% of rdg + 5 dgts |
4000uA | 1uA |
± 1.8% of rdg + 5 dgts |
40.00mA | 10uA | |
400.0mA | 100uA | |
20A | 10mA | ± 3.0% of rdg + 7 dgts |
Overload Protection : 0.5A / 1000V and 10A / 500V Fuse
AC Response : 50 Hz to 400 Hz
Maximum Input : 400mA DC or 400mA AC rms on uA
/ ma ranges, 20A DC or AC rms on 20A range
Note: 10A continuous, 20A for 30 seconds max with a 15 minute cool down interval
Resistance (Auto-ranging)
Range | Resolution | Accuracy |
400.0Ω | 0.1Ω | ± 1.2% of rdg ± 4 dgts |
4000kΩ | 1Ω | ± 1.0% of rdg ± 2 dgts |
40.00kΩ | 10Ω |
± 1.2% of rdg ± 2 dgts |
400.0kΩ | 100Ω | |
4.00MΩ | 1kΩ | |
40.00MΩ | 10kΩ | ± 2.0% of rdg ± 7 dgts |
Input Protection : 600V DC or 600V AC rms
Capacitance (Auto-ranging)
Range | Resolution | Accuracy |
4.000nF | 1pF | ± 5.0% of rdg ± 0.2 nF |
40.00nF | 10 pF | ± 5.0% of rdg ± 7 dgts |
400.0nF | 0.1nF |
± 3.0% of rdg ± 5 dgts |
4.000uF | 1nF | |
40.00uF | 10nF | |
200.0uF | 0.1uF | ± 5.0% of rdg ± 5 dgts |
Input Protection : 600V DC or 600V AC rms
Frequency (Auto-ranging)
Range | Resolution | Accuracy |
9.999Hz | 0.001 Hz |
± 1.5% of rdg ± 5 dgts |
99.99Hz | 0.01 Hz | |
999.9Hz | 0.1 Hz |
± 1.2% of rdg ± 3 dgts |
9.999kHz | 1Hz | |
99.99kHz | 10Hz | |
999.9kHz | 100Hz | |
9.999MHz | 1kHz | ± 1.5% of rdg ± 4 dgts |
Sensitivity : > 0.5V RMS while ≤ 1MHz
Sensitivity : > 3V RMS while > 1MHz
Overload protection : 600V DC or AC rms
Duty Cycle
Range | Resolution | Accuracy |
0.1%~99.9% | 0.1% | ± 1.2% of rdg ± 2 dgts |
Pulse width : > 100us, < 100ms
Frequency width : 5Hz - 150kHz
Sensitivity : > 0.5V RMS
Overload protection :600V DC or AC rms
Diode Text
Test Current | Resolution | Accuracy |
0.3mA typical | 1 mV | ± 10% of rdg ± 5 dgts |
Open circuit voltage : 1.5V DC typical
Overload protection : 600V DC or AC rms
Audible continuity
Audible threshold : Less than 150Ω
Test current : < 0.3 mA
Overload protection : 600V DC or AC rms