Kusam Meco KM 878 DIGITAL INSULATION MULTIMETER TRUE RMS
Kusam Meco KM 878 DIGITAL INSULATION MULTIMETER TRUE RMS
(Based On 10 Reviews)
The Kusam Meco KM 878 is a versatile True RMS Digital Insulation Multimeter designed for professionals requiring precise electrical measurements across a wide range of applications.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 31,599.00
(GST inclusive price) i₹41,000.00
( - 23% OFF )
Description
OPTIONAL ACCESSORIES
What's in the box?
|
Rating & Reviews
Rating
• Sensing : AC, True RMS
• Display : 3-5/6 digits 6000 Counts Backlight LCD Display.
• 61 Segments Analog Bar Graph : 60 per second max.
• Auto or Manual-ranging mode.
• Auto Power Off.
• Polarity : Automatic
• Update Rate : 5 per second nominal
• Earth Continuity Test : 110mA @20 Ω range, 220mA @2.0 Ω range.
Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard test of 1 Ω with a duty cycle of 5 seconds on & 25 seconds off.
• Insulation Resistance @ 1mA Test Current :
50V output Voltage :25mA, 100V output Voltage : 45mA
250V output Voltage : 85mA, 500V output Voltage : 170mA
1000V output Voltage : 440mA
Tester can perform at least 950 Insulation Tests with new alkaline batteries at room temperature.
These are standard tests of 1000V into 1MΩ with a duty cycle of 5 seconds on and 25 seconds off.
• Operating Temperature : -10°C ~ 40°C
• Relative Humidity : Maximum relative humidity 90% for temperature up to 28°C decreasing linearly to 50% relative humidity at 40°C.
• Pollution degree : 2
• IP Rating : IP40
• Storage Temperature : -20°C ~ 60°C, < 80% R.H. (with battery removed)
• Altitude : Operating below 2000m
• Temperature Coefficient : Nominal 0.15 x (specified accuracy)/ °C @(-10°C~18°C or 28°C~40°C), or otherwise specified.
• Low Battery : approx. 4.6V
• Power Supply : Four Alkaline AA batteries
• Power Consumption : 4.5mA typical except : ACV +Hz & VFD ACV +Hz : 7.0mA
• APO Timing : Idle for 20 minutes
• APO Consumption : 50 µA typical
• Dimension: 208(L) X 103(W) X 64.5(H) mm with holster
• Weight : 635 gm with holster.
AC VOLTAGE | ||
Range | Resolution | Accuracy |
50Hz ~ 60Hz | ||
6.000 V | 1 mV | ±(1%rdg + 3dgts) |
60.00 V | 10 mV | |
600.0 V | 100 mV | |
1000 V | 1 V | |
60Hz ~ 1kHz | ||
6.000 V | 1 mV | ±(2%rdg + 3dgts) |
60.00 V | 10 mV | |
600.0 V | 100 mV | |
1000 V | 1 V | |
1kHz ~ 3kHz | ||
6.000 V | 1 mV | ±(2%rdg + 3dgts) |
60.00 V | 10 mV | |
600.0 V | 100 mV | Unspecified |
1000 V | 1 V | |
3kHz ~ 5kHz | ||
6.000 V | 1 mV | ±(4%rdg + 5dgts) |
60.00 V | 10 mV | |
600.0 V | 100 mV | Unspecified |
1000 V | 1 V |
DC VOLTAGE | ||
Range | Resolution | Accuracy |
6.000 V | 1 mV | ±(0.2%rdg + 3dgts) |
60.00 V | 10 mV | |
600.0 V | 100 mV | ±(0.3%rdg + 3dgts) |
1000 V | 1 V |
VFD AC VOLTAGE | ||
Range | Resolution | Accuracy |
10Hz ~ 45Hz | ||
600.0 V | 100 mV | ±(4%rdg + 5dgts) |
45Hz ~ 200Hz | ||
600.0 V | 100 mV | ±(2%rdg + 5dgts) |
200Hz ~ 440Hz | ||
600.0 V | 100 mV | ±(7%rdg + 5dgts ) |
ACmV | ||
Range | Resolution | Accuracy |
50Hz ~ 60Hz | ||
60.00 mV | 10 μV | ±(1%rdg + 3dgts) |
600.0 mV | 100 μV | |
60Hz ~ 3kHz | ||
60.00 mV | 10 μV | ±(2%rdg + 3dgts) |
600.0 mV | 100 μV | |
3kHz ~5kHz | ||
60.00 mV | 10 μV | ±(3%rdg + 5dgts) |
600.0 mV | 100 μV |
DCmV | ||
Range | Resolution | Accuracy |
60.00 mV | 10 μV | ±(0.5%rdg + 3dgts) |
600.0 mV | 100 μV | ±(0.1%rdg + 3dgts) |
DCmA | ||
Range | Resolution | Accuracy |
60.00 mV | 10 μV | ±(0.5%rdg + 3dgts) |
600.0 mV | 100 μV |
DCmA | ||
Range | Resolution | Accuracy |
50Hz ~ 1kHz | ||
60.00 mV | 10 μV | ±(1.5%rdg + 3dgts) |
600.0 mV | 100 μV |
INSULATION RESISTANCE | |||
Test Voltage | Resolution | Test Current | Accuracy |
50 V | 3.000MΩ, 30.00MΩ, 55.0MΩ | 1mA @50kW | ±(1.5%rdg + 5dgts) |
100 V | 3.000MW, 30.00MW, 110.0MW | 1mA @100kW | |
250 V | 3.000MW, 30.00MW, 275.0MW | 1mA @250kW | |
500 V | 3.000MW, 30.00MW, 300.0MW,550.0MW | 1mA @500kW | |
1000 V | 3.000MW, 30.00MW, 300.0MW | 1mA @1MW | ±(1.5%rdg + 5dgts) |
3000MW | ±(2.0%rdg + 5dgts) | ||
25.0GW | ±(10%rdg + 5dgts) |
~ Hz Line Level Frequency | ||
Function Range | Sensitivity (sine Rms) | Range |
60 mV | 6 mV | 10Hz ~ 50kHz |
600 mV | 60 mV | 10Hz ~ 100kHz |
6 V | 0.6 V | 10Hz ~ 20kHz |
60 V | 6 V | |
600 V | 60 V | 10Hz ~ 3kHz |
1000 V | 600 V | |
VFD 600 V | 60~240 V | 10Hz ~ 440Hz |
60 mA | 6 mA | 10Hz ~ 5kHz |
600 mA | 60 mA |
RESISTANCE (OHMS) | ||
Range | Resolution | Accuracy |
600.0 Ω | 100 mΩ | ±(0.9%rdg + 5dgts) |
6.000 kΩ | 1 Ω | ±(0.9%rdg + 2dgts) |
60.00 kΩ | 10 Ω | |
600.0 kΩ | 100 Ω | |
6.000 MΩ | 1 kΩ | ±(1.2%rdg + 3dgts) |
60.00 MΩ | 10 kΩ | ±(3.0%rdg + 6dgts) |
CAPACITANCE | ||
Range | Resolution | Accuracy |
3.000 μF | 1 nF | ±(1.5%rdg + 5dgts) |
30.00 μF | 10 nF | |
300.0 μF | 100 nF | |
3000 μF | 1 μF | |
30.00 mF | 10 μF | ±(10%rdg + 5dgts) |
TEMPERATURE | |
Range | Accuracy |
-50.0ºC ~ 0.0ºC | 2% + 3ºC |
0.0ºC ~50.0ºC | 2.2ºC |
50.0ºC ~ 537.0ºC | 2% + 2ºC |
-58.0ºF ~ 32.0ºF | 2% + 6ºF |
32.0ºF ~ 122.0ºF | 4.4ºF |
122.0ºF ~ 999.0ºF | 2% + 4ºF |
DIODE TESTER | ||
Range | Resolution | Accuracy |
2.000 V | 1 mV | ±(1.5%rdg + 4dgts) |
Rating & Reviews
Rating
Similar Products
Request Callback
We will get in touch with you
More From Brands
Enter your requirement details!
We will get in touch with you.
Share This Product
Reach Us
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034
For Support
8920884830
Send Us Email
info@insuzo.com
Copyright © 2024. Insuzo
All Rights Reserved.