Item(s) Added To Your Bag
Metravi 901-IV TRMS Compact Digital Multimeter with Analogue Bargraph & Double Insulation
Metravi 901-IV TRMS Compact Digital Multimeter with Analogue Bargraph & Double Insulation
Metravi 901-IV TRMS Compact Digital Multimeter with Analogue Bargraph & Double Insulation
The Metravi 901‑IV TRMS Multimeter is a high‑precision, 6000‑count, autoranging handheld tester. It measures AC/DC voltage and current, resistance, capacitance, frequency, temperature, diode and continuity—with full safety protection up to 600 V.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL PRODUCTS
SECURE PAYMENTS
1 YEAR WARRANTY
AUTHORIZED DISTRIBUTOR
B2B INVOICES
₹ 5,379.00
(GST inclusive price) i₹7,229.00
( - 26% OFF )
Description
What's in the box?
|
The instrument complies with: EN61010-1.
Insulation: Class2, Double insulation. Overvoltage category: CATIII 600V, CATII 1000V. Display: 6000 counts LCD display with function indication.
Polarity: Automatic, (-) negative polarity indication.
Overrange: "OL" mark indication.
AC Response: True RMS (50 Hz or 60 Hz)
True RMS: The term stands for “Root-Mean-Square”, which represents the method of calculation of the voltage or current value. Average responding multimeters are calibrated to read correctly only on sine waves and they will read inaccurately on non- sine wave or distorted signals. True rms meters read accurately on either type of signal.
Low battery indication: The ' ' is displayed when the battery voltage drops below the operating level. Measurement rate: 2 times per second, nominal. Auto power off: Meter automatically shuts down after approx. 15 minutes of inactivity.
Operating environment: 0ºC to 50ºC (32 ºF to 122 ºF) at < 70% relative humidity.
Storage temperature: -20ºC to 60ºC (-4 ºF to 140 ºF) at < 80% relative humidity. For inside use, max height: 2000m
Pollution degree: 2
Power: One 9V battery , NEDA 1604, IEC 6F22. Dimensions: 150 (H) x 70 (W) x 48 (D) mm Weight: Approx.: 255g.
Hold : To freeze displayed data
Max/Min : To record max/min values
Input Limits | |
Function | Maximum Input |
V DC orV AC | 1000V DC /VAC |
A DC/AC | 10A DC/AC (30 sec. max every 15minutes) |
Frequency, Resistance, Capacitance, Duty Cycle, Diode test, Continuity | 600V DC/AC |
Temperature | 600V DC/AC |
DC Voltage
Range | Resolution | Accuracy |
600.0mV | 0.1mV | ±0.5% of rdg + 2 dgts |
6.000V | 1mV |
±1.2% of rdg + 2 dgts |
60.00V | 10mV | |
600.0V | 100mV | |
1000V | 1V | ±1.5% of rdg + 2 dgts |
Input Impedance : 7.8MΩ. Maximum Input : 1000V DC or 1000V AC rms. |
AC Voltage (T-RMS)
Range | Resolution | Accuracy |
6.000V | 1mV |
±1.5% of rdg ±10 dgts |
60.00V | 10mV | |
600.0V | 100mV | |
1000V | 1V | ±2.0% of rdg + ±10 dgts |
Input Impedance : 7.8MΩ. Frequency Range : 50 to 60Hz Maximum Input : 1000V DC or 1000V AC rms. |
DC Current
Range | Resolution | Accuracy |
6A | 1mA | ±2.5% of rdg ± 5 dgts |
10A | 10mA | |
Input Impedance : 7.8MΩ. Frequency Range : 50 to 60Hz Maximum Input : 1000V DC or 1000V AC rms. |
AC Current (T-RMS)
Range | Resolution | Accuracy |
6A | 1mA | ±3.0% of rdg ± 5 dgts |
10A | 10mA | |
Overload Protection : 10A / 250V Fuse. Frequency Range : 50 to 60 Hz Maximum Input : 10A DC or AC rms on 10A AC range. |
Resistance
Range | Resolution | Accuracy |
600.0Ω | 0.1Ω | ±1.2% of rdg + 4 dgts |
6.00kΩ | 1Ω | ±1.0% of rdg + 2 dgts |
60.00kΩ | 10Ω | ±1.2% of rdg + 2 dgts |
600.0kΩ | 100Ω | |
6.000MΩ | 1kΩ | ±2.0% of rdg ± 10 dgts |
60.00MΩ | 10kΩ | ±5.0% of rdg ± 10 dgts |
Maximum Input : 600V DC or 600V AC rms. |
Capacitance (Auto-ranging)
Range | Resolution | Accuracy |
40.00nF | 1pF | ±5.0% of rdg±50 dgts |
400.0nF | 0.1nF |
±3.0% of rdg ±5 dgts |
4.000uF | 1nF | |
40.00uF | 10nF | |
400.0uF | 0.1uF | ±5.0% of rdg ±5 dgts |
4000uF | 1uF | |
Maximum Input : 600V DC or 600V AC rms. |
Diode test
Test current | Resolution | Accuracy |
0.3mA typical | 1 mV | ±10% of rdg ± 5 dgts |
Open circuit voltage : 1.5V DC typical Overload protection : 600V DC or AC rms. |
Frequency (Auto-ranging)
Range | Resolution | Accuracy |
9.999Hz | 0.001Hz | ±1.5% of rdg ±5 dgts |
99.99Hz | 0.01Hz | |
999.9Hz | 0.1Hz |
±1.2% of rdg ±3 dgts |
9.999kHz | 1Hz | |
99.99kHz | 10Hz | |
999.9kHz | 100Hz | |
20MHz | 1kHz | ±1.5% of rdg ±4 dgts |
Sensitivity : >0.5V RMS while ≤ 1MHz ; Sensitivity : >3V RMS while >1MHz ; Overload protection : 600V DC or 600V AC rms. |
Duty Cycle
Range | Resolution | Accuracy |
0.1%~ 99.9% | 0.1% | ±1.2% of rdg ±2 dgts |
Pulse width : >100us, <100ms; Frequency : 5Hz - 150kHz Sensitivity : >0.5V RMS Overload protection : 600V DC or 600V AC rms. |
Temperature
Range | Resolution | Accuracy |
-20ºC~+ 760ºC | 1 ºC | ±3% of rdg
±5 ºC/9ºF |
-4 ºF~+ 1400 ºF |
1ºF | |
Sensor : Type K Thermocouple Overload protection : 600V DC or AC rms.. |
Audible threshold : Less than 100Ω;
Test current : < 0.3mA
Overload protection : 600V DC or AC rms.
Similar Products
Request Callback
We will get in touch with you
More From Brands
Enter your requirement details!
We will get in touch with you.