Metravi 70-MOTS Motorised Oil Test Set
Metravi 70-MOTS Motorised Oil Test Set
(Based On 10 Reviews)
The Metravi 70-MOTS Oil Test Kit is a portable device designed for testing the dielectric strength of insulating oils. It ensures accurate, reliable results for preventive maintenance in electrical systems, enhancing safety and equipment performance in the field.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL PRODUCTS
SECURE PAYMENTS
1 YEAR WARRANTY
AUTHORIZED DISTRIBUTOR
B2B INVOICES
₹ 52,833.00
(GST inclusive price) i₹71,111.00
( - 26% OFF )
Description
What's in the box?
|
Rating & Reviews
Rating
Type | Motor operated to uniformly increase the output voltage between 0 to 0 to 50 KV or 60KV or 70 KV 'or' 75 KV 'or' 80 KV 'or 90 KV or 100 KV 'br 120KV with the help of continuously variable Auto Transformer at 2 KV/Sec. Approx |
Input | 230/240V AC 50 Hz single phase AC supply. |
Output | 0-50 KV or 60KV 'or 70 KV or 75 KV 'or' 80 KV 'or' 90 KV 'or 100 KV or 120KV with center tap earthed infinitely variable. (For Example the output shall be 50kV for a 50kV Oil Test Set, the output shall be 60kV for a 60kV Oil test Set, so on and so forth) |
Frequency | 50 HZ |
Max. generated test voltage | |
Between transformer | 50KV or 60 KV 'or' 70 KV 'or 75 KV 'or 80 KV or 90 KV 'or 100 KV or 120 KV Rms. (For Example the Maximum terminals generated test voltage between transformer terminals shall be 50kV for a 50KV Oil Test Set and shall be 60kV for a 60KV Oil Test Set, so on and so forth) |
Between transformer | 25KV 'or 30 KV 'or' 35 KV 'or 37.5 KV 'or 40 KV or 45 KV 'or 50 KV 'or' 60 KV Rms. (For Example the maximum terminals & earth voltage generated between the transformer terminals and earth shall be 25kV for a 50KV Oil Test set and shall be 30kV for a 60kV Oil Test Set, so on and so forth) |
Capacity | 500VA or 600VA 'or' 700VA 'or 750VA or 800VA 'or 900VA 'or 1000VA 'or 1200VA intermittent (For example the capacity shall be 500VA for a 50kV Oil Test Set and 600VA for a 60kV Oil Test Set, so on and so forth) |
ISS reference | IS: 6792/1972 latest |
Indication | Mains ON and HT ON indicating NEON lamps |
Metering | Volt meter-panel meter marked 0-50KV or 0-60KV 60 KV'or 70 KV 'or 75 KV or 80 KV or 90 KV or 100 KV 'or 120 KVshould indicate the applied voltage to liquid dielectric and also have memory effect. |
Aux | The unit will have necessary switches, fuses indicating lamps, push button operated contactor etc. for efficient operation of unit |
INTERLOCKING | 1) Zero start interlocking 2) HT chamber door interlocking 3) Low level and high level interlocking for drive motor |
SAFETY MEASURES | 1) Zero interlocking arrangement before energizing HT transformer after each test 2) A transparent protective hood on the lest cup with a interlocking micro switch for operator safety so that the HV transformers cannot be energized or remain energized when the transparent protective hood is opened |
Test Cell | Methyl Methacrylate cell having effective volume between 300 to 500 ml |
Electrodes | Brass polished spherical electrodes 12.5 to 13 mm diameter mounted on a horizontal axis which can be set to a gap of 2.5 mm. |
Transformer | Resin encapsulated HT transformer. |
Construction | Naturally air cooled. Portable sheet metal casting provided with handles consisting of control section and HT transformer in single cubicles |
Rating & Reviews
Rating
Similar Products
Request Callback
We will get in touch with you
More From Brands
Enter your requirement details!
We will get in touch with you.
Share This Product
Reach Us
The Office Address
305 P.P. Trade Center, Netaji Subash Place, Pitampura, Delhi - 110034
For Support
8920884830
Send Us Email
info@insuzo.com
Copyright © 2024. Insuzo
All Rights Reserved.