Item(s) Added To Your Bag

Fluke 373 True-RMS AC Clamp Meter

Click To Zoom

Fluke 373 True-RMS AC Clamp Meter

Fluke 373 True-RMS AC Clamp Meter

(Based On 10 Reviews)

Fluke 373 True-RMS AC Clamp Meter is a great choice for AC-only current measurement situations. Featuring True RMS AC voltage and current measurements you can measure AC current to 600 A and AC voltage to 600V. The 373 also measures DC voltage to 600 V and resistance to 6000 Ω.

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL Products
100% ORIGINAL Products Details

100% ORIGINAL Products

SECURE Payments
SECURE Payments Details

SECURE Payments

₹ 29,845.00

(GST inclusive price) i
  • Base Value: ₹ 25292.4
  • GST: (18) % ₹ 4552.6
  • Total Value ₹ 29845

₹40,470.00

( - 26% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • A top performing True-RMS current clamp for AC-only current measurements to 600 A
  • Measures AC and DC voltage to 600 V
  • Measures resistance to 6000 Ω with continuity detection
  • Offers state of the art signal processing to provide stable readings even in noisy electrical environments

 

Fluke 373 True RMS AC Clamp Meter does the job for any AC-only current measurement application

Fluke 373 True-RMS AC Clamp Meter is a great choice for AC-only current measurement situations. Featuring True RMS AC voltage and current measurements you can measure AC current to 600 A and AC voltage to 600V. The 373 also measures DC voltage to 600 V and resistance to 6000 Ω.

To make it even easier to use, the large, easy-to-read backlit display provides better visibility in dimly lit conditions. And the 373 automatically sets the correct measurement range based on the voltage present when you power up, so you do not need to move the switch while taking a measurement. When you put it all together, you’ll find the Fluke 373 offers everything you need, plus a little more.

 

Other Useful Capabilities:

  • Provides True-RMS voltage and current measurements to accurately measure non-linear signals
  • Automatically selects a measurement range based on voltage present so you don’t need to change the switch positions while taking a measurement
  • Presents readings on a large, easy-to-read backlit display
  • Features CAT IV 300 V, CAT III 600 V safety ratings
  • Comes with a soft carrying case and three-year warranty
  • Runs on two AA alkaline batteries

 

What's in the box?

  • 373 True-RMS AC Clamp Meter
  • (1 pair) TL75 test leads
  • Soft carrying case
  • Five AA Alkaline Batteries (Installed)
  • Quick Reference Guide

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image

Product Specifications

Electrical Specifications
AC Current
Range600.0 A
Resolution0.1 A
Accuracy2 % ± 5 digits (48 – 62 Hz)
Crest Factor (50/60 Hz)2.5 @ 600 A
AC Voltage
Range600.0 V
Resolution0.1 V
Accuracy1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range600.0 V
Resolution0.1 V
Accuracy1 % ± 5 digits
Resistance
Range600.0 Ω/6000 Ω
Resolution0.1 Ω/1 Ω
Accuracy1 % ± 5 digits
Continuity Beeper30 Ω
Capacitance
Range10.0 – 100.0 μF / 1000 μF
Resolution0.1 μF/1 μF
Accuracy1.9 % ± 2 digits
Mechanical Specifications
Size (L x W x H)232 mm x 85 mm x 45 mm
Weight370 g
Environmental Specifications
Operating Temperature-10 °C to +50 °C
Storage Temp-40 °C to +60 °C
Operating HumidityNon condensing (< 10 °C)
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Operating Altitude3000 meters
Storage Altitude12,000 meters
EMI, EMCMeets all applicable requirements in EN61326-1:2006
Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Safety ComplianceANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV
Pollution Degree 2
EN/IEC 61010-2-32:2002
EN/IEC 61010-031:2002/A1:2008
Batteries2 AA, NEDA 15A, IEC LR6

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image